Rylee Banks Portfolio

NEXT Law Firm

PARTITION SCHEDULE

DOOR

METAL SEPERATOR

HARDWOOD FLOOR

HARDWOOD FLOOR

W1

4131

Associate 4131

Legal Assistant 4159

Facilities Manager 4210

Multi Purpose 4227

Lactation 4106

IAF07

Section 5

5

CONCRETE

1/4" = 1'-0"

WINDOW DETAIL

WINDOW DETAIL

WOOD TO WOOD TRANSITION

GLASS

2

GLASS

6" = 1'-0"

MULLION

METAL SEPERATOR HARDWOOD FLOOR

END CAP

END CAP

MULLION MATE

CARPET

MULLION MATE

C JOINT

C JOINT

INSULATION

GYP

INSULATION

GYP

PARTITION DETAIL AT WINDOW

4 PARTITION DETAIL AT MULLION WINDOW

1

1 1/2" = 1'-0"

1 1/2" = 1'-0"

PLYWOOD

PARTITION GENERAL NOTES

CONCRETE

1. DO NOT SCALE DRAWINGS TO DETERMINE INTENDED DIMENSIONS OR TO LAY OUT WORK. 2. FIELD VERIFY EXISTING CONDITIONS. REPORT DISCREPANCIES BETWEEN ACTUAL CONDITIONS AND CONTRACT DOCUMENTS TO THE ARCHITECT IN WRITING AND OBTAIN CLARIFICATION PRIOR TO SUBMITTING PROPOSALS OR COMMENCING WORK. 3. DIMENSIONS ARE TO THE FACE OF FINISHED WALL SURFACE UNLESS NOTED OTHERWISE. 4. REFER TO THE REFLECTED CEILING PLANS FOR PROPOSED CEILING HEIGHTS AND COORDINATED LOCATIONS OF ALL ELECTRICAL, HVAC AND FIRE PROTECTION DEVICES TO BE INSTALLED IN OR ON FINISHED CEILINGS. 5. UNLESS NOTED OR SHOWN OTHERWISE, DUCTWORK, PIPING, CONDUIT AND STRUCTURAL ELEMENTS ARE NOT TO BE EXPOSED WITHIN FINISHED SPACES. 6. REPLACE OR PATCH DAMAGED FIRE PROOFING MATERIAL THAT HAS BEEN DAMAGED OR REMOVED DUE TO DEMOLITION WORK OR OTHER CONSTRUCTION ACTIVITY. REFER TO THE PROJECT MANUAL AND THE FIREPROOFING SCHEDULE FOR MATERIAL SPECIFICATIONS AND SPECIFIC DESIGN REQUIREMENTS FOR EACH ASSEMBLY AFFECTED. 7. MECHANICAL AND/OR ELECTRICAL WORK REQUIRED TO COMPLETE THIS PROJECT MAY REQUIRE WORK IN PORTIONS OF THE EXISTING BUILDING BEYOND THE GENERAL CONTRACT LIMIT LINES OF ARCHITECTURAL WORK. REMOVAL AND RESTORATION OF EXISTING BUILDING ELEMENTS OR FINISHES, REPAIRS TO DAMAGED FINISHES, THE ERECTION AND REMOVAL OF TEMPORARY PARTITIONS AND/OR SIGNAGE ASSOCIATED WITH THIS WORK MUST BE COMPLETED TO THE SATISFACTION OF THE OWNER AS PART OF THIS PROJECT 8. THE KEYING OF PARTITION TYPES ON THE PLANS IS INTENDED TO AID THE CONTRACTOR IN UNDERSTANDING THE VARIOUS CONDITIONS LIKELY TO BE ENCOUNTERED. THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING WHAT MATERIAL (TYPES AND SIZES OF FURRING) IS REQUIRED TO COMPLETE THE PROJECT AS SHOWN. 9. WHERE NEW PARTITIONS ABUT AND ALIGN WITH EXISTING PARTITIONS OR OTHER SURFACES, FINISHED SURFACES SHALL BE IN THE SAME PLANE. 10. PROVIDE REDUCER STRIPS OR TRANSITION STRIPS WHERE FINISH FLOORING MATERIALS HAVE DIFFERENT THICKNESSES AND/OR DIFFERENT MATERIALS ABUT. 11. PROVIDE 6”HIGH, 16GA. SHEET METAL REINFORCEMENT FOR WALL MOUNTED EQUIPMENT UNLESS NOTED OTHERWISE TO BE OF MORE SUBSTANTIAL REINFORCEMENT 12. WOOD USED FOR FRAMING AND BLOCKING SHALL BE FIRE-RETARDANT TREATED WOOD, U.L. LABELED. 13. RESTORE EXISTING FINISH SURFACES DAMAGED AS A RESULT OF CONSTRUCTION ACTIVITIES ASSOCIATED WITH THIS PROJECT. 14. DISCREPANCIES IN THE DOCUMENTS ARE TO BE REPORTED TO THE ARCHITECT IMMEDIATELY. UNLESS OTHERWISE DIRECTED THE HIGHER DEGREE OF PERFORMANCE, THE BETTER QUALITY, OR GREATER QUANTIY

W1 - TYPICAL INTERIOR WALL

W2 - TYPICAL INTERIOR WALL - ACOUSTIC

CEILING

STRUCTURE

TANSITION

1

6" = 1'-0"

STRUCTURE

CEILING

6" METAL STUDS

FINISH SCHEDULE

TITLE:

TITLE:

6" METAL STUDS

Finished Legend/ Schedule

Partition Schedule

GYP

SECTION @HEAD

ID Order Number

GYP

Key Name

LOCATION

TYPE

MANUFACTURER

PRODUCT INFORMATION

FINISH

NOTES

ID

SECTION @HEAD

FLOOR FINISH CP1

THROUGHOUT THROUGHOUT

CARPET

INTERFACE VICCARBE

MONOCROME: CONCRETE 101839

CONCRETE MATT OAK

FLOOR FINISH 1 FLOOR FINISH 1

FINISH LEGEND

WD1

WOOD

MATT OAK

BASE FINISH B1 WALL FINISH P1

INSULATION

REFER TO PLAN RESILIENT BASE

TARKET

BASEWORKS

SNOWBOUND

BASE FINISH 2

INDICATES ACCENT TREATMENT

INSULATION

6" METAL STUDS

PLAN VIEW

THROUGHOUT

PAINT

COALASSE

COLOR: MILK 4145

MILK

WALL FINISH 3

INDICATES TWO WALL FINISHES, REFER TO ELEVATIONS FOR ADDITIONAL INFO

757 S. Alameda Street Suite 400 Los Angeles, CA 90021

757 S. Alameda Street Suite 400 Los Angeles, CA 90021

CEILING FINISH CT1

ADDRESS:

ADDRESS:

PLAN VIEW

THROUGHOUT

ACOUSTIC CEILING TILE

ROCKFON

COLOR: PURE WHITE

EGGSHELL

CEILING FINISH 4

INDICATES COUNTER TOP TREATMENT

SURFACES WD1

XX/XX

MILLWORK AND DESK WOOD

VICCARBE COALASSE

MATT OAK

MATT OAK

SURFACES 5 SURFACES 5

INDICATES CASEWORK TREATMENT

WD2

OFFICES

WOOD

MEDIUM AMBER CHERRY FLAT CUT HIGH SHEEN

V12C

Rylee Banks 09/26/2025 As indicated

Rylee Banks 09/26/2025 As indicated

DRAWN BY:

DRAWN BY:

MISCELLANEOUS AC1

DATE:

DATE:

WORKSTATION

ACOUSTICAL SHEET ACOUSTICAL SHEET ACOUSTICAL SHEET

MDC

ZINTRA ZTR4727

TWILIGHT

MISCELLANEOU S MISCELLANEOU S MISCELLANEOU S

6

FLOOR

INDICATES CHANGE OF MATERIALS, SEE TRANSITION DETAILS

SECTION @BASE

SCALE:

SCALE:

AC2

WORKSTATION

MDC

ZINTRA ZTR4721

CADET

6

FLOOR

SECTION @BASE

A5.00

A2.00

AC4

WORKSTATION

MDC

ZINTRA ZTR4722

BRICK

6

2 NON-RATED NON-BEARING PARTITION

3 NON-RATED NON-BEARING ACOUSTIC PARTITION

1 1/2" = 1'-0"

1 1/2" = 1'-0"

ACOUSTICAL CEILING TILE

FINISH LEGEND

GENERAL FINISH NOTES

CEILING PLAN GENERAL NOTES

ACOUSTICAL SHEET OVER WORKSTATIONS CEILING AT 9' - 6"

COVE LIGHTING IN OFFICES CEILING AT 10' - 1"

LEGEND

A. FINISH SYSTEMS DESCRIBE THE FINISH SPECIFICATION FOR THE VERTICAL SURFACE OF ALL FINISHES APPLIED TO A PARTITION. IF DISCREPANCY OCCURS, CONTACT THE ARCHITECT FOR CLARIFICATION PRIOR TO STARTING WORK WITHIN THE SUBJECT AREA. B. WORKMANSHIP SHALL BE THE BEST OF ITS RESPECTIVE KINDS FOR EACH OF THE VARIOUS TRADESD EMPLOYED. C. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR EXAMINING AND CONFIRMING ALL SUBSTRATE CONDITIONS WHERE NEW MATERIALS ARE APPLIED. SUBSTRATE SHALL BE SMOOTH, FREE OF DEFECTS AND SHALL CONFORM TO THE REQUIREMENTS OF THE FINISHED MATERIAL MANUFACTURERS WRITTEN RECOMMENDATIONS. D. PATCHING COMPOUND: FLOOR COVERING MANUFACTURER'S RECOMMENDED PRODUCT, SUITABLE FOR CONDITIONS, AND COMPATIABLE WITH ADHESIVE AND FLOOR COVERING, IN THE ABSENCE OF ANY RECOMMENDATION FROM FLOORING MANUFACTURER, SEE SPECIFICATIONS. E. ALTERNATE FLOOR ADHESIVE: FLOOR COVERING MANUFACTURER'S RECOMMENDED PRODUCT, SUITABLE FOR MOISTURE AND PH CONDITIONS PRESENT AND MEET LOW-VOC REQUIREMENTS. IN ABSENCE OF ANY RECOMMENDATION FROM FLOORING MANUFACTURER, PROVIDE PRODUCT RECOMMENDED BY ADHESIVE MANUFACTURE AS SUITABLE FOR SUBSTRATE AND FLOOR COVERING AND CONDITIONS PRESENT. F. REMEDIAL FLOOR COATING: SINGLE OR MULTI LAYER COATING/OVERLAY COMBINATION INTENDED BY IT'S MANUFACTURER TO RESIST WATER VAPOR TRANSMISSION TO A DEGREE SUFFICIENT TO MEET FLOORING MANUFACTURER'S EMISSION LIMITS, RESISTANT TO THE LEVEL OF PH FOUND AND SUITABLE FOR ADHESION OF FLOORING WITHOUT FURTHER TREATMENT. G. UPON COMPLETION OF INSTALLATION OF POCELAIN/CERAMIC TILE, CONTRACTOR TO CLEAN ALL TILE SURFACES PER MANUFACTURERS WRITTEN RECOMMENDATIONS SO THEY ARE FREE OF FORIEGN MATTER. SEALL ALL GROUT WITH (2) COATS OF MANUFACTURERS RECOMMENDED GROUT SEALER. PROHIBIT FOOT AND/OR WHEEL TRAFFIC FROM TILED FLOORS FOR AT LEATS 7 DAYS AFTER GROUTING IS COMPLETE. H. FINISH SUBSITITIONS SHALL BE APPROVED BY ARCHITECT ONLY AND PER SPECIFICATIONS. SEE SPECIFICATIONS FOR SUBMITTAL REQUIREMENTS FOR ANY SUBSITUTIONS. I. DURING INSTALLATION OF CARPET, CONTRACTOR MUST COMPLY WITH CARPET MANUFACTURERS WRITTEN RECOMMENDED INSTALLATION METHODS. THIS INCLUDES BUT DOES NOT ALWAYS APPLY TO SEAM SEALERS, GLUE, TERMINATION OF ALL SEAMS AND EXPOSED EDGES. J. UPON COMPLETION OF INSTALLTION OF CARPET, CONTRACTOR TO REMOVE VISIBLE ADHESIVE, SEAM SEALER AND OTHER SURFACE BLEMISHES USING CLEANER RECOMMENDED BY CARPET MANUFACTURER. COMPLY WITH CRI 104, SECTION 15: "PROTECTION OF INDOOR INSTALLATION." REFER TO FINISH AND MATERIAL LEGEND FOR ARCHITECT DESIRED INSTALL. K. PROVIDE AND CONTINUE SCHEDULED FLOORING FROM PARTITION TO PARTITION AND UNDER MILLWORK UNLESS NOTED OTHERWISE.

A. ALL DEVICES LOCATED WITHIN LAY-IN CEILING TILES SHALL BE CENTERED EACH WAY IN THE TILE, UNLESS NOTED OTHERWISE. B. MECHANICAL AND ELECTRICAL DEVICES ARE SHOWN ON THIS DRAWING FOR LOCATION ONLY. FOR INFORMATION REGARDING DEVICE SPECIFICS, REFER TO ELEC. AND MECHANICAL DRAWINGS AND SPECIFICATIONS. C. ALL WALLS AND CEILING PREPARES MUST TO MATCH THE EXISTING COLORS TEXTURES AND MATERIALS. D. REPLACEMENT MOLDING SHOULD BE MATCHING THE EXISTING. E. CONTRACTOR TO VERIFY ALL EXISTING CEILING MEASUREMENTS NEEDED PRIOR TO STARTING THE WORK.

INDICATES ACCENT TREATMENT

LED

ACOUSTICAL CEILING TILE

CEILING TILE

SUSPENDED LIGHT PENDANT - RE: ELEC.

SUSPENDED LIGHT PENDANT - RE: ELEC.

SUSPENDED LIGHT PENDANT - RE: ELEC.

GYP 6" METAL STUD INSULATION

WIRE

INDICATES TWO WALL FINISHES, REFER TO ELEVATIONS FOR ADDITIONAL INFO

ACOUSTICAL SHEET

GYP

CEILING MOUNTED LIGHT - RE: ELEC.

CEILING MOUNTED EXIT LIGHTING

SUSPENDED LIGHT PENDANT - RE: ELEC.

INDICATES COUNTER TOP TREATMENT

XX/XX

WALL MOUNTED EXIT LIGHTING

INDICATES CASEWORK TREATMENT

ACOUSTICAL PANELING

1 1/2" = 1'-0" COVE LIGHTING

3

2

1 1/2" = 1'-0"

INDICATES CHANGE OF MATERIALS, SEE TRANSITION DETAILS

A.F.F. Acoustical Sheet

- ---

A.F.F. Acoustical Ceiling tile 10' - 1"

Associate 4131

Associate 4133

Associate 4132

Partner 4130

Partner 4129

Associate 4128

Associate 4127

Associate 4125

Library 4119

Partner 4124

Associate 4126

Associate 4121

Partner 4123

Associate 4120

Associate 4122

Associate 4134

118 SF

118 SF

116 SF

142 SF

143 SF

132 SF

123 SF

115 SF

418 SF

137 SF

114 SF

115 SF

139 SF

116 SF

115 SF

115 SF

CP1 P1 B1 CT1

CP1 P1 B1 CT1

CP1 P1 B1 CT1

CP1 P1 B1 CT1

CP1 P1 B1 CT1

CP1 P1 B1 CT1

CP1 P1 B1 CT1

CP1 P1 B1 CT1

CP1 P1 B1 CT1

CP1 P1 B1 CT1

CP1 P1 B1 CT1

CP1 P1 B1 CT1

CP1 P1 B1 CT1

CP1 P1 B1 CT1

CP1 P1 B1 CT1

P1

Associate 4134

Associate 4133

Associate 4132

Associate 4131

Partner 4130

Partner 4129

Associate 4128

Associate 4127

Associate 4126

Associate 4125

Partner 4124

Partner 4123

Associate 4122

Associate 4121

Associate 4120

Library 4119

115 SF

118 SF

116 SF

118 SF

142 SF

143 SF

132 SF

123 SF

114 SF

115 SF

137 SF

139 SF

115 SF

115 SF

116 SF

418 SF CP1

CP1

CP1

CP1

CP1

CP1

CP1

CP1

CP1

CP1

CP1

CP1

CP1

CP1

CP1

CP1

B1 CT1

WD1

WD1

WD1

WD1

WD1

WD1

WD1

WD1

WD1

WD1

WD1

WD1

WD1

WD1

WD1

WD1

WD1

WD1

WD1

WD1

CP1

P1

CP1

CP1

CP1

CP1

Legal Assistant 4158

Legal Assistant 4159

WD1

Legal Assistant 4232

Legal Assistant 4158

Legal Assistant 4232

Intern 4180

Junior Associate 4205

IT Help 4161

Legal Assistant 4159

Intern 4174

Intern 4174

IT Help 4162

45 SF

CP1

Junior Associate 4205

IT Help 4161

IT Help 4162

Legal Assistant 4181

Intern 4180

Legal Assistant 4175

Legal Assistant 4181

45 SF

Legal Assistant 4175

80 SF CP1 P1 B1 CT1

49 SF

Partner 4118

CP1 P1 B1 CT1

45 SF

49 SF

47 SF

47 SF

WD1

45 SF

50 SF

50 SF

44 SF

Junior Associate 4203

Partner 4118

Paralegal 4157

Intern 4160

80 SF

47 SF

44 SF

47 SF

47 SF

46 SF

47 SF

Junior Associate 4203

46 SF

Legal Assistant 4199

144 SF

CP1

Intern 4160

Junior Associate 4204

Paralegal 4173

Junior Associate 4204

Legal Assistant 4178

WD1

HR Coordinator 4164

IT Admin 4163

Legal Assistant 4199

93 SF

144 SF

45 SF

45 SF

IT Admin 4163

Legal Assistant 4172

Paralegal 4179

Legal Assistant 4178

Legal Assistant 4172

93 SF

HR Coordinator 4164

CP1 P1 B1 CT1

46 SF

CP1

45 SF

93 SF

Paralegal 4179

Paralegal 4173

Facilities Manager 4210

50 SF

93 SF

49 SF

46 SF

43 SF

46 SF

Paralegal 4157

CP1 P1 B1 CT1 CP1 P1 B1 CT1 CP1 P1 B1 CT1

43 SF

46 SF

49 SF

49 SF

46 SF

Partner 4117

Office Manager 4209

46 SF

Focus Room 4206

49 SF

50 SF

96 SF

HR Recruiter 4165

HR Recruiter 4165

CP1

WD1

Partner 4117

45 SF

CP1

Focus Room 4206

IT Analyst 4166

IT Analyst 4166

151 SF

100 SF

70 SF

CP1 P1 B1 CT1

CP1 P1 B1 CT1

WD1

46 SF

46 SF

151 SF

70 SF

NIC

Facilities Manager 4210

44 SF

CP1 P1 B1 CT1

44 SF

Resource 4202

Focus Room 4207

Office Manager 4209

NIC

CP1

WD1

NIC

Focus Room 4207

Partner 4116

NIC

HR Manager 4211

96 SF

202 SF

Resource 4202

72 SF

100 SF

WD1

A.F.F. Acoustical Ceiling tile 10' - 1"

Partner 4116

CP1 P1 B1 CT1

72 SF

152 SF

114 SF

CP1

5'-3"

6'-0"

HR Manager 4211

202 SF

WD1

152 SF

Pantry 4208

Pantry 4208

CP1 P1 B1 CT1

CP1

114 SF

A.F.F. Custom Wood Ceiling

9'-4"

97 SF

97 SF

Partner 4115

IT Manager 4212

Partner 4115

Multi Purpose 4227

CP1 P1 B1 CT1

IT Manager 4212

149 SF

119 SF

Finance Anaylst 4168

Legal Assistant 4225

589 SF CP1 P1 B1 CT1

Finance Anaylst 4168

WD1

149 SF

WD1

CP1

52 SF Finance Billing 4169 Finance Billing 4170

WD1 WD1 B1

Finance Billing 4169

WP1

8'-6"

5'-4 1/2"

119 SF

CP1 P1 B1 CT1

CP1

55 SF

49 SF

55 SF

Large Conference Room 4101

Work Cafe 4226

Finance Manager 4213

Virtual Hearing Room 4201

Large Conference Room 4101

52 SF

Partner 4114

Work Cafe 4226

Legal Assistant 4225

Partner 4114

Finance Billing 4170

CP1 P1 B1 CT1

617 SF

Finance Accounts 4171

CP1 P1, WD2 B1 CT1

209 SF

118 SF

553 SF

617 SF

Finance Manager 4213

49 SF

Finance Accounts 4171

163 SF

209 SF

49 SF

WD2

WD2

163 SF

49 SF

51 SF

Multi Purpose 4227

TITLE:

TITLE:

7'-8 1/2"

11'-5 1/2"

Virtual Hearing Room 4201

CP1

CP1

118 SF

Reflected Ceiling Plan

Finish Plan

CP1

51 SF

WD1

WD1

589 SF

WD1

WD1

553 SF

WD1

CL

WD1

WD1

WD2 P1 B1 CT1

WD1

WD1

WD1

WD1

WD1

Reception 4217

CP1

CP1

Medium Conference Room 4102

Medium Conference Room 4103

CP1

CP1

CP1

CP1

CP1

Small Conference Room 4104

Small Conference Room 4105

Lactation 4106

P1

P1

Huddle Room 4107

Huddle Room 4108

Case Room 4109

Case Room 4110

Case Room 4111

Case Room 4112

Managing Partner 4113

CP1 P1 B1 CT1

CP1 P1 B1 CT1

CP1 P1 B1 CT1

CP1 P1 B1 CT1

CP1 P1 B1 CT1

379 SF

CP1 P1 B1 CT1

CP1 P1 B1 CT1

CP1 P1 B1 CT1

CP1 P1 B1 CT1

128 SF CP1 P1 B1 CT1

CP1 P1 B1 CT1

Managing Partner 4113

152 SF

154 SF

207 SF

211 SF

217 SF

121 SF

129 SF

142 SF

138 SF

141 SF

366 SF

366 SF

757 S. Alameda Street Suite 400 Los Angeles, CA 90021

757 S. Alameda Street Suite 400 Los Angeles, CA 90021

ADDRESS:

ADDRESS:

LEVEL 4 - FINISH PLAN

Medium Conference Room 4102

Medium Conference Room 4103

Small Conference Room 4105

Lactation 4106

Huddle Room 4107

Huddle Room 4108

Case Room 4109

Case Room 4110

Case Room 4111

Case Room 4112

1

Reception 4217

1/8" = 1'-0"

GYP-1

A.F.F. Acoustical Ceiling tile 9' - 6"

11' - 6"

154 SF

128 SF

217 SF

121 SF

129 SF

142 SF

138 SF

141 SF

A.F.F.

379 SF

207 SF

211 SF

A.F.F. Acoustical Ceiling tile 10' - 1"

Rylee Banks 09/26/2025 As indicated

Rylee Banks 09/26/2025 As indicated

Small Conference Room 4104

DRAWN BY:

DRAWN BY:

DATE:

DATE:

152 SF

LEVEL 4 - RCP

1

SCALE:

SCALE:

1/8" = 1'-0"

A3.00

A5.01

N

N

0'

4'

8'

16'

32'

0'

4'

8'

16'

32'

20

FALL 2025

Design 5

Made with FlippingBook - Share PDF online