General note for all stoves and fireplaces 1. Heating Capacity will vary depending on the design of the home, climate, elevation, operation and venting configuration. See Zone chart on page 44. 2.Depth is front of stove to back of shroud. 3. Dimensions can vary depending on installation variables. See manuals for exact specifications.
HEATING ZONES
TECHNICAL DIMENSIONS
4. All Jøtul gas stoves and fireplaces include approved fire safety screen 5. Conforms to Amendment 15 of Canada’s Energy Efficiency Regulations
HEATING CAPACITY BY ZONE
JØTUL GF 200 DV II LILLEHAMMER - Page 8
100 - 800 sq. ft.
Heating Capacity 1 Min/Max Heat Input
Jøtul Gas Stoves & Inserts US & Canada Heat Capacity by Zone
11,400-20,000 (NG) 8,450-18,000 (LP)
(BTU/hr)
Efficiency Steady State
75.05%
EnerGuide Rating 5 ( DV MV Canada)
73.63% (NG) 72.14% (LP)
Venting
4” x 6 5/8”
Dimensions Stove Height
25”
Stove Height w/ opt. long legs
27 1/4”
Leg Width
22” 15”
Depth 2
Clearances Rear
0” (zero clearance)
Side
3”
Corner 2” Refer to manual for additional measurements and clearances
JØTUL GF 300 DV ALLAGASH - Page 10
Heating Capacity 1 Min/Max Heat Input
400 - 1300 sq.ft.
14,000-26,000 (NG) 14,000-26,000 (LP)
(BTU/hr)
Efficiency Steady State
75.30%
This heating capacity zone chart is to be used as a guideline only. Square footage measurements may differ due to climate, building construction, and location of stove. Heating capacity on the product page is based on Zone 4.
EnerGuide Rating 5 (DV MV Canada)
66.27% (NG) 66.27% (LP)
Venting
4” x 6 5/8”
Dimensions Stove Height
27 3/4” 25 1/2” 22 1/2”
Min/Max Input
Zone 1
(sq. ft.) Zone 2
(sq. ft.) Zone 3
(sq. ft.) Zone 4
(sq. ft.) Zone 5
(sq.ft) Zone 6
Stove Height w/ opt. short legs
Model
(BTU/Hr)
(sq. ft.)
Leg Width
Depth 2
16”
Jøtul GF 200 Lillehammer
11 - 20,000
100
200
400
600
700
800
Clearances Rear
2” 3”
Side
Jøtul GF 300 Allagash
14 - 26,000
400
600
800
1000
1200
1300
Corner 2” Refer to manual for additional measurements and clearances
Jøtul GF 400 DV Sebago
18 - 32,000
700
1000
1200
1400
1600
2000
Jøtul GF 400 BV Sebago
22 - 40,000
800
1200
1400
1600
1800
2200
JØTUL GF 300 BV ALLAGASH - Page 10
Jøtul GF 500 Portland
13 - 40,000
800
1200
1400
1600
1800
2200
Heating Capacity 1 Min/Max Heat Input
400 - 1300 sq.ft.
15,000-26,000 (NG) 13,500-26,000 (LP)
Jøtul GF 160
15 - 24,000
200
300
500
800
900
1000
(BTU/hr)
Efficiency Steady State
82.31%
Jøtul GF 305 DV IPI
18 - 28,000
400
600
800
1000
1200
1300
EnerGuide Rating 5 (BV MV Canada)
61.12% (NG) 61.12% (LP)
Venting
4”
Jøtul GF 370
18 - 28,000
400
600
800
1000
1200
1300
Dimensions Stove Height
27 3/4” 25 1/2” 22 1/2” 16 1/2”
Jøtul GF 520
16 - 30,000
700
1000
1200
1400
1600
1800
Stove Height w/ opt. short legs
Leg Width
Depth 2
Jøtul GI 535 DV IPI New Harbor
11 - 32,000
700
1000
1200
1400
1600
2000
Clearances Rear
2” 3”
Jøtul GI 635 DV IPI Newcastle
10 - 40,000
800
1200
1400
1600
1800
2200
Side
Corner 3” Refer to manual for additional measurements and clearances
Jøtul GI 545 DV Winter Harbor
13 - 30,000
600
800
1000
1200
1400
1800
Jøtul GI 645 DV Astrid
20 - 38,000
800
1000
1400
1600
1800
2200
Gas catalog 2023 / PAGE 44