Gas Brochure 2004

General note for all stoves and fireplaces 1. Heating Capacity will vary depending on the design of the home, climate, elevation, operation and venting configuration. See Zone chart on page 44. 2.Depth is front of stove to back of shroud. 3. Dimensions can vary depending on installation variables. See manuals for exact specifications.

HEATING ZONES

TECHNICAL DIMENSIONS

4. All Jøtul gas stoves and fireplaces include approved fire safety screen 5. Conforms to Amendment 15 of Canada’s Energy Efficiency Regulations

HEATING CAPACITY BY ZONE

JØTUL GF 200 DV II LILLEHAMMER - Page 8

100 - 800 sq. ft.

Heating Capacity 1 Min/Max Heat Input

Jøtul Gas Stoves & Inserts US & Canada Heat Capacity by Zone

11,400-20,000 (NG) 8,450-18,000 (LP)

(BTU/hr)

Efficiency Steady State

75.05%

EnerGuide Rating 5 ( DV MV Canada)

73.63% (NG) 72.14% (LP)

Venting

4” x 6 5/8”

Dimensions Stove Height

25”

     

Stove Height w/ opt. long legs

27 1/4”

    

Leg Width

22” 15”

  

Depth 2

Clearances Rear

0” (zero clearance)

Side

3”

Corner 2” Refer to manual for additional measurements and clearances

 

JØTUL GF 300 DV ALLAGASH - Page 10

Heating Capacity 1 Min/Max Heat Input

400 - 1300 sq.ft.

14,000-26,000 (NG) 14,000-26,000 (LP)

      

(BTU/hr)

      

Efficiency Steady State

75.30%

This heating capacity zone chart is to be used as a guideline only. Square footage measurements may differ due to climate, building construction, and location of stove. Heating capacity on the product page is based on Zone 4.

EnerGuide Rating 5 (DV MV Canada)

66.27% (NG) 66.27% (LP)

Venting

4” x 6 5/8”

 

Dimensions Stove Height



27 3/4” 25 1/2” 22 1/2”

Min/Max Input

Zone 1

(sq. ft.) Zone 2

(sq. ft.) Zone 3

(sq. ft.) Zone 4

(sq. ft.) Zone 5

(sq.ft) Zone 6

Stove Height w/ opt. short legs

Model

(BTU/Hr)

(sq. ft.)

Leg Width

 

Depth 2

16”

   

Jøtul GF 200 Lillehammer

11 - 20,000

100

200

400

600

700

800

Clearances Rear

  

2” 3”

Side

Jøtul GF 300 Allagash

14 - 26,000

400

600

800

1000

1200

1300

    

 

Corner 2” Refer to manual for additional measurements and clearances

 

Jøtul GF 400 DV Sebago

18 - 32,000

700

1000

1200

1400

1600

2000

Jøtul GF 400 BV Sebago

22 - 40,000

800

1200

1400

1600

1800

2200

JØTUL GF 300 BV ALLAGASH - Page 10

Jøtul GF 500 Portland

13 - 40,000

800

1200

1400

1600

1800

2200

Heating Capacity 1 Min/Max Heat Input

400 - 1300 sq.ft.

15,000-26,000 (NG) 13,500-26,000 (LP)

Jøtul GF 160

15 - 24,000

200

300

500

800

900

1000

(BTU/hr)

Efficiency Steady State

82.31%

Jøtul GF 305 DV IPI

18 - 28,000

400

600

800

1000

1200

1300

EnerGuide Rating 5 (BV MV Canada)

61.12% (NG) 61.12% (LP)

Venting

4”

Jøtul GF 370

18 - 28,000

400

600

800

1000

1200

1300

 

Dimensions Stove Height

     

27 3/4” 25 1/2” 22 1/2” 16 1/2”

Jøtul GF 520

16 - 30,000

700

1000

1200

1400

1600

1800

Stove Height w/ opt. short legs

Leg Width

Depth 2

Jøtul GI 535 DV IPI New Harbor

11 - 32,000

700

1000

1200

1400

1600

2000

Clearances Rear



2” 3”

Jøtul GI 635 DV IPI Newcastle

10 - 40,000

800

1200

1400

1600

1800

2200

  

Side

Corner 3” Refer to manual for additional measurements and clearances

 

Jøtul GI 545 DV Winter Harbor

13 - 30,000

600

800

1000

1200

1400

1800

Jøtul GI 645 DV Astrid

20 - 38,000

800

1000

1400

1600

1800

2200

Gas catalog 2023 / PAGE 44

Gas catalog 2023 / PAGE 45

Made with FlippingBook flipbook maker