General note for all stoves and fireplaces 1. Heating Capacity will vary depending on the design of the home, climate, elevation, operation and venting configuration. See Zone chart on page 44. 2.Depth is front of stove to back of shroud. 3. Dimensions can vary depending on installation variables. See manuals for exact specifications.
General note for all stoves and fireplaces 1. Heating Capacity will vary depending on the design of the home, climate, elevation, operation and venting configuration. See Zone chart on page 44. 2.Depth is front of stove to back of shroud. 3. Dimensions can vary depending on installation variables. See manuals for exact specifications.
TECHNICAL DIMENSIONS
TECHNICAL DIMENSIONS
4. All Jøtul gas stoves and fireplaces include approved fire safety screen 5. Conforms to Amendment 15 of Canada’s Energy Efficiency Regulations
4. All Jøtul gas stoves and fireplaces include approved fire safety screen 5. Conforms to Amendment 15 of Canada’s Energy Efficiency Regulations
JØTUL GF 300 DV IPI ALLAGASH - Page 11
JØTUL GF 400 DV IPI SEBAGO - Page 13
Heating Capacity 1 Min/Max Heat Input
700 - 2000 sq.ft.
Heating Capacity 1 Min/Max Heat Input
400 - 1300 sq.ft.
17,000-32,000 (NG) 14,000-30,000 (LP)
15,000-26,000 (NG) 12,000-24,000 (LP)
(BTU/hr)
(BTU/hr)
Efficiency Steady State
77.02%
Efficiency Steady State
73.57%
EnerGuide Rating (DV Canada)
68.19% (NG) 67.69% (LP)
EnerGuide Rating (DV Canada)
69.23% (NG) 69.99% (LP)
Venting
4” x 6 5/8”
Venting
4” x 6 5/8”
Dimensions Stove Height
Dimensions Stove Height
28 1/2” 26 1/4” 26 1/2”
27 3/4” 25 1/2” 22 1/2”
Stove Height w/ opt. short legs
Stove Height w/ opt. short legs
Leg Width
Leg Width
Depth 2
18”
Depth 2
16”
Clearances Rear
Clearances Rear
2” 3”
2” 3”
Side
Side
Corner 2” Refer to manual for additional measurements and clearances
Corner 2” Refer to manual for additional measurements and clearances
* 14” snorkel shown
JØTUL GF 500 DV PORTLAND - Page 14
JØTUL GF 400 DV SEBAGO - Page 12
Heating Capacity 1 Min/Max Heat Input
700 - 2000 sq.ft.
Heating Capacity 1 Min/Max Heat Input
800 - 2200 sq.ft.
18,000-32,000 (NG) 16,000-32,000 (LP)
12,800-40,000 (NG) 14,000-39,500 (LP)
(BTU/hr)
(BTU/hr)
Efficiency Steady State
75.60%
Efficiency Steady State
74.26%
EnerGuide Rating 5 (DV MV Canada)
63.18% (NG) 63.18% (LP)
EnerGuide Rating 5 (DV MV Canada)
76.01% (NG) 76.52% (LP)
Venting
4” x 6 5/8”
Venting
4” x 6 5/8”
Dimensions Stove Height
Dimensions Stove Height
28 1/2” 26 1/4” 26 1/2”
30”
Stove Height w/ opt. short legs
Stove Height w/ opt. short legs
27 3/4” 27 3/4”
Leg Width
Leg Width
Depth 2
18”
Depth 2
20”
Clearances Rear
Clearances Rear
2” 3”
1 1/2”
Side
Side
2”
Corner 2” Refer to manual for additional measurements and clearances
Corner 2” Refer to manual for additional measurements and clearances
JØTUL GF 400 BV SEBAGO - Page 12
JØTUL GF 500 DV IPI PORTLAND - Page 15
Heating Capacity 1 Min/Max Heat Input
800 - 2200 sq.ft.
Heating Capacity 1 Min/Max Heat Input
800 - 2200 sq.ft.
12,800-40,000 (NG) 14,000-39,500 (LP)
22,000-40,000 (NG) 20,000-40,000 (LP)
(BTU/hr)
(BTU/hr)
Efficiency Steady State
74.76%
Efficiency Steady State
82.56%
EnerGuide Rating (DV Canada)
76.01% (NG) 76.52% (LP)
EnerGuide Rating 5 (BV MV Canada)
64.74% (NG) 64.74% (LP)
Venting
4” x 6 5/8”
Venting
4”
Dimensions Stove Height
Dimensions Stove Height
30”
28 1/2” 26 1/4” 26 1/2” 20 1/2”
Stove Height w/ opt. short legs
27 3/4” 27 3/4”
Stove Height w/ opt. short legs
Leg Width
Leg Width
Depth 2
20”
Depth 2
Clearances Rear
Clearances Rear
1 1/2”
3” 3”
Side
2”
Side
Corner 2” Refer to manual for additional measurements and clearances
Corner 3” Refer to manual for additional measurements and clearances
Gas catalog 2023 / PAGE 46
Gas catalog 2023 / PAGE 47
Made with FlippingBook flipbook maker