Gas Brochure 2004

General note for all stoves and fireplaces 1. Heating Capacity will vary depending on the design of the home, climate, elevation, operation and venting configuration. See Zone chart on page 44. 2.Depth is front of stove to back of shroud. 3. Dimensions can vary depending on installation variables. See manuals for exact specifications.

General note for all stoves and fireplaces 1. Heating Capacity will vary depending on the design of the home, climate, elevation, operation and venting configuration. See Zone chart on page 44. 2.Depth is front of stove to back of shroud. 3. Dimensions can vary depending on installation variables. See manuals for exact specifications.

TECHNICAL DIMENSIONS

TECHNICAL DIMENSIONS

4. All Jøtul gas stoves and fireplaces include approved fire safety screen 5. Conforms to Amendment 15 of Canada’s Energy Efficiency Regulations

4. All Jøtul gas stoves and fireplaces include approved fire safety screen 5. Conforms to Amendment 15 of Canada’s Energy Efficiency Regulations

JØTUL GF 160 DV MILLIVOLT SYSTEM - Page 16

JØTUL GF 370 DV MILLIVOLT SYSTEM - Page 22

Heating Capacity 1 Min/Max Heat Input

200 - 1000 sq.ft.



Heating Capacity 1 Min/Max Heat Input

400 - 1300 sq.ft.

15,800-24,000 (NG) 19,800-24,000 (LP)





18,170-28,000 (NG) 20,750-24,000 (LP)

(BTU/hr)

(BTU/hr)

Efficiency Steady State

73.91%

Efficiency Steady State

76.30%

EnerGuide Rating (DV MV Canada)

68.21% (NG) 69.14% (LP)

 

EnerGuide Rating (DV MV Canada)

71.14% (NG) 64.13% (LP)

Venting

4” x 6 5/8”



Venting

4” x 6 5/8”



Dimensions Stove Height

Dimensions Stove Height

 

35 1/2” 17 3/4” 17 3/4”

 

45 1/2” 18 1/4” 17 7/8”

Leg Width



Width Depth 2

Depth 2

 

Clearances Rear

Clearances Rear

2”

3” 7”

Side

7 3/8”

Side

Corner 3 3/8” Refer to manual for additional measurements and clearances

Corner 5” Refer to manual for additional measurements and clearances

            

 

JØTUL GF 160 DV IPI - Page 18

JØTUL GF 370 DV II IPI - Page 24

Heating Capacity 1 Min/Max Heat Input

200 - 1000 sq.ft.



15,800-24,000 (NG) 19,800-24,000 (LP)





Heating Capacity 1 Min/Max Heat Input

400 - 1300 sq.ft.

(BTU/hr)

18,170-28,000 (NG) 20,750-24,000 (LP)

Efficiency Steady State

74.49%

(BTU/hr)

EnerGuide Rating (DV Canada)

67.91% (NG) 68.53% (LP)

 

Efficiency Steady State

79.30%

Venting

4” x 6 5/8”



EnerGuide Rating (DV Canada)

71.14% (NG) 64.13% (LP)



Dimensions Stove Height

Venting

4” x 6 5/8”

 

35 1/2” 17 3/4” 17 3/4”

 

Dimensions Stove Height

Leg Width



45 1/2” 18 1/4” 17 7/8”

Depth 2

 

Width Depth 2

Clearances Rear

2”

Clearances Rear

Side

7 3/8”

3” 7”

Corner 3 3/8” Refer to manual for additional measurements and clearances

Side

            

Corner 5” Refer to manual for additional measurements and clearances

 

JØTUL GF 520 DV MILLIVOLT SYSTEM - Page 26

JØTUL GF 305 DV IPI - Page 20

Heating Capacity 1 Min/Max Heat Input

400 - 1300 sq.ft.



700 - 1,800 sq.ft.

Heating Capacity 1 Min/Max Heat Input

18,707-28,000 (NG) 22,370-28,000 (LP)

16,500-30,000 (NG) 16,500-29,000 (LP)

(BTU/hr)

(BTU/hr)

Efficiency Steady State

73.16%

Efficiency Steady State

71.72%

EnerGuide Rating (DV Canada)

67.98% (NG) 68.14% (LP)

              €      ‚ ƒ 

EnerGuide Rating (DV MVCanada)

63.49% (NG) 64.61% (LP)

Venting

4” x 6 5/8”



Venting

4” x 6 5/8”

Dimensions Stove Height

Dimensions Stove Height

33 3/8” 21 3/4” 16 1/4”

1.5"

39”

Leg Width

Width Depth 2

23 3/8”

Depth 2

67"

17 1/2”

Clearances Rear

70.25"

Clearances Rear

2”

1 1/2”

Side

2”(R side) 6”(L side)

39"

Side

10”

Corner 3” Refer to manual for additional measurements and clearances

Corner 3 3/8” Refer to manual for additional measurements and clearances

Gas catalog 2023 / PAGE 48

Gas catalog 2023 / PAGE 49

Made with FlippingBook flipbook maker