Gas Brochure 2004

General note for all stoves and fireplaces 1. Heating Capacity will vary depending on the design of the home, climate, elevation, operation and venting configuration. See Zone chart on page 44. 2.Depth is front of stove to back of shroud. 3. Dimensions can vary depending on installation variables. See manuals for exact specifications.

TECHNICAL DIMENSIONS

4. All Jøtul gas stoves and fireplaces include approved fire safety screen 5. Conforms to Amendment 15 of Canada’s Energy Efficiency Regulations

JØTUL GF 520 DV IPI - Page 26

Heating Capacity 1 Min/Max Heat Input

700 - 1,800 sq.ft.

16,500-30,000 (NG) 16,500-29,000 (LP)

(BTU/hr)

Efficiency Steady State

71.72%

EnerGuide Rating (DV Canada)

64.19% (NG) 65.47% (LP)

Venting

4” x 6 5/8”

Dimensions Stove Height

39”

1.5"

Width Depth 2

23 3/8”

17 1/2”

67"

Clearances Rear

70.25"

1 1/2”

Side

10”

39"

Corner 3 3/8” Refer to manual for additional measurements and clearances

JØTUL GI 545 DV WINTER HARBOR - Page 28

  

A Minimum Back Wall Height B Minimum Back Wall Width C Minimum Fireplace Depth D Minimum Opening Height

20” 20”

 



15”

A

D

 

B

20” 30”

 

 

C

E

Minimum Opening Width

A: Hearth Protection Width from fireplace opening • Unit flush: Min 3 1/8” • Unit raised minimum 6” off floor: 0” B: Hearth Protection Depth • Unit flush with hearth 12” • Unit raised min. 6” off floor: 0” C: Side Trim Clearance • Up to 6” depth, from fireplace center line: 20 3/4” D: Side Room Wall Clearance • From the fireplace center line: 27”

E

 

 

 

F

E

E: Top Trim Clearance • From hearth: 37 1/4” F: Mantel • 37 1/4” at 4”/ 39 3/4” at 12” depth With Mantel Heatshield: 32 1/4” at 4”/ 36” at 12” depth EnerGuide Rating 5 (DV MV Canada) 63.28% (NG) 65.39% (LP)

B

A

C

D

JØTUL GI 645 DV ASTRID - Page 28

3/4’’ 19 mm

A Minimum Back Wall Height B Minimum Back Wall Width C Minimum Fireplace Depth D Minimum Opening Height

19”

AIR SPACE - DO NOT RESTRICT

23 3/4”

16 1/2”

A

D

B

24”

23-3/4’’ 603.3 mm

E

Minimum Opening Width

33 3/4”

C

22-3/8’’ 567 mm

18-3/4’’ 475.8 mm

A: Hearth Protection Width from fireplace opening • Unit flush: Min 4 5/8” • Unit raised minimum 6” off floor: 0” B: Hearth Protection Depth • Unit flush with hearth 12” • Unit raised min. 6” off floor: 0” C: Side Trim Clearance • Up to 6” depth, from fireplace center line: 21 1/8” D: Side Room Wall Clearance • From the fireplace center line: 26 5/8” E: Top Trim Clearance • From hearth: 46”/ 38 1/2” with Mantel Heatshield F: Mantel: 46” at 4”/ 48 1/8” at 12” depth

E

7-1/8’’ 179.83 mm

1-3/8’’ 33.1 mm

16’’ 406.4 mm

F

E

23-1/2’’ 597 mm

3-1/4’’ 82 mm

AIR INTAKE

B

A

C

EXHAUST

13-3/8’’ 340.4 mm

D

With Mantel Heatshield: 38 1/2” at 4”/ 42 1/2” at 12” depth EnerGuide Rating 5 (DV MV Canada) 64.55% (NG) 64.57% (LP)

9-5/8’’ 245 mm

100’’ 2540 mm

IF POWER CORD EXITS RIGHT SIDE OF UNIT SUBTRACT FIREBOX WIDTH 100"- 33.5" = 66 1/2"

2-1/8’’ 53.4 mm

33-1/2’’ 850.9 mm

Gas catalog 2023 / PAGE 50

Made with FlippingBook flipbook maker