(9) ELECTRICAL CONNECTIONS
Defender Downdraft Table s runs on 208/230/460VAC power, 60Hz
The incoming power is connected to the unit at the conduit connection located on the outer side of the
motor housing on the unit.
(10) When power is brought into the Downdraft Table through the EMT Conduit fitting, it will enter the electrical box at the front/top side of the motor housing. (11) First make the ground connection into the grounding terminal block. (12) The incoming power wires must be terminated on the incoming side of the power disconnect switch / emergency shut off switch (L1, L2, L3). (13) Primary branch circuit protection must be provided by the end user. The breaker must have an IC trip rating of 30kA. Please see the following chart for recommended breaker size. (14) A wiring diagram for the Downdraft Table is provided in Appendix C. (15) The full load amperage varies depending on the unit configuration. Please see the following chart for motor and unit full load amperage ratings (FLA).
Page 13
sales@clean-air.com
1-866-665-1829
www.clean-air.com
www.clean-air.com
13
Made with FlippingBook Online newsletter maker