(14) TROUBLESHOOTING
Problems
Possible Cause
Recommended
Course of Action
GENERAL
1. Check Power Supply
Fan does not start running.
1. No Power Supply
2. Turn on Main Switch.
Downdraft table does not
2. Main Switch Off
function.
3. Repair or replace motor
3. Motor defective
4. Replace ON/OFF Button
4. ON/OFF Button Defective
5. Check current settings and reset
5. Overload Relay Tripped
overload relay.
6. Replace overload relay
6. Overload Relay Defective
7. Close and lock both doors
7. Left and/or right door open
8. Correct wiring for proper supply
8. Unit not wired for available voltage
voltage.
ReInsufficient Flow.
1. Filter Cartridges need replacing
1.Replace both filter cartridges
Downdraft Table does not function properly.
2. Replace HEPA filter cartridge
2. Baffle filter and/or Metal Mesh dirty
2. Clean Prefilters
3. Fan Rotation Backwards
3. Proper fan rotation is counterclockwise
from the front of the unit. Re-wire if fan is
rotating clockwise
4. Access doors open or not closed tight
4. Check that all access doors are in place
and secured
Insufficient Flow.
5. Silencer exhaust area restricted
5. Check fan exhaust area for obstructions,
remove any material or debris.
Downdraft Table does not function properly.
7. Dust Tray overfilled
7. Clean out dust storage area
Page 26
sales@clean-air.com
1-866-665-1829
www.clean-air.com
www.clean-air.com
26
Made with FlippingBook Online newsletter maker