The following Warranty Standards are applicable only to warranted items stated in Section II of this Limited Warranty. Read Section II to determine if the following Warranty Standards apply. WARRANTY STANDARDS • A. YEAR 1 COVERAGE ONLY
1. FOUNDATIONS
OBSERVATION
ACTION REQUIRED
COMMENTS
CRAWL SPACE
SECTION III.
1.10 Cracks in poured concrete foundation walls.
Surface patching and epoxy injections are examples of acceptable repair methods. Shrinkage cracks of 1/4 in. or less are common and should be expected. Surface patching and epoxy injections are examples of acceptable repair methods. Shrinkage cracks of 1/4 in. or less are common and should be expected. Maintaining adequate ventilation and moisture control, including seasonal adjustment of vent openings, is considered Owner maintenance. Maintaining adequate ventilation and moisture control, including seasonal adjustment of vent openings, is considered Owner maintenance. Expansion/contraction joint is placed to control cracking. This is not a deficiency. In rooms not initially finished as living areas or where a floor or a portion of a floor surface has been designed for specific drainage purposes, a slope which exceeds 3/8 in. within a 32 in. measurement is acceptable. Disintegration caused by erosion due to salt, chemicals, implements used and other factors beyond Builder’s control is not a war- ranted deficiency. Minor impressions in floor covering are not considered significant imperfections. Surface patching and epoxy injections are examples of acceptable repair methods. Shrinkage cracks are common and should be expected. Surface patching and epoxy injections are examples of acceptable repair methods. Shrinkage cracks are common and should be expected. Surface patching and epoxy injections are examples of acceptable repair methods. Shrinkage cracks are common and should be expected.
Builder will correct any crack which exceeds 1/4 in. in width.
1.11 Cracks in block or veneer wall.
Builder will correct cracks greater than 1/4 in. in width.
1.12 Inadequate ventilation.
Builder will install properly sized louvers or vents.
1.13 Condensation on walls, joists, support columns and other components of the crawl space area.
No action required.
SLAB ON GRADE
1.14 Cracks appear at control joints. 1.15 Uneven concrete floors in finished areas.
No action required.
Builder will correct areas in which Defect exceeds 3/8 in. within a 32 in. measurement.
1.16 Disintegration of concrete floor surface.
Builder will correct disintegrated surfaces caused by improper placement of concrete.
1.17 Crack in concrete floor which ruptures or sig- nificantly impairs perfor - mance of floor covering. 1.18 Cracks in attached garage slab. 1.19 Cracks in concrete floor of unfinished area (no floor covering) or in areas not designed for living. 1.20 Cracks in visible face of foundation.
Builder will correct so Defect is not readily noticeable when floor covering is in place.
Builder will correct cracks which exceed 1/4 in. in width or vertical displacement.
Builder will correct cracks which exceed 1/4 in. in width or vertical displacement.
Builder will correct cracks in excess of 1/4 in. in width.