A.2.2. Apollon Group - Strataflex - Online Catalogues

STRATAFLEX Technical Information

*All data is for reference only and cannot be guaranteed.

1. COMPOSITION & ROLL SIZE ● Composition : Poly Vinyl Chloride (PVC) ● Standard Roll Size : 1.22m x 50m (some designs are in 30 or 40m rolls). Cut length is available on request. 2. LOWEST TEMPERATURE FOR INSTALLATION 12 °C 3. IDEAL TEMPERATURE FOR INSTALLATION 20 - 25 °C 4. STORAGE CONDITIONS Store the product in good condition, below 38 °C, avoid direct sunlight and high humidity. Use within 1 year of purchase. 5. DIMENSION STABILITY TEST [Test method] : 150 x 150mm of STRATAFLEX was applied to the centre of a 200 x 200mm aluminium panel. One crossing surface cut was made in centre of the finish. After 2 days at 65 °C, the maximum gap in the cut was measured. [Test result] : Not greater than 0.3mm 6. THERMAL DURABILITY TEST [Test method] : STRATAFLEX was applied to an aluminium panel. It was kept for 12 days and exposed to various temperatures. [Test result] : No peeling or colour change occurred between - 30 °C to + 65 °C 7. SUNSHINE CARBON ARK LIGHT TEST [Test method] : 250 hours lighting of sunshine, using Carbon Ark Light testing machine at 63 °C of black panel temperatures. [Test result] : No change 8. ABRASION TEST [Test method] : Final abrasion point by Taber testing machine (wheel : CS-17, 1kg weight) [Test result] : Greater than 7000 cycles 9. HIGH TEMPERATURE DURABILITY TEST [Test method] : STRATAFLEX was applied to an aluminium panel and kept for 28 days at 65 °C [Test result] : No change in adhesion 10. HIGH HUMIDITY DURABILITY TEST [Test method] : STRATAFLEX was applied to an aluminium panel and kept for 28 days at 40 °C RH 90%. [Test result] : No change in adhesion 11. LOW TEMPERATURE IMPACT TEST [Test method] : Du-Pont impact test (0 °C, 100g, 100mm, 1/2 inch diameter) [Test result] : No change 12. TEST FOR ANTI-BACTERIAL [Test method] : JISZ2801 The Bacteria were cultivated at 35 °C and over 90% RH for 24 hours [Test result] :

13. TEST FOR ANTI-MOULD [Test result] :

Grade

Items for test TA-4701 to TA-4803 Other products

10 days later 0 2

14 days later 0 2

21 days later 0 3

28 days later 0 3

*Grade : 0 - 4 (It shows the condition of mould's growth) 0 : Not found

1 : Under 10% of surface area 2 : 10 - 30% of surface area 3 : 31 - 60% of surface area 4 : 61 - 100% of surface area

* Test method : ASTM-G21, at 28 °C ± 2 °C and over 95% RH * Tested by Tokyo Metropolitan Industrial Technology Research Institute

14. ∞PVC Please note that under Japanese law, all PVC items must carry the ∞ PVC logo which is printed on the reverse of the STRATAFLEX products. This may become visible if adhered to translucent substrates.

16 hours after soaking in room temperature water

10 hours after xenon weathering test

Tested Bacteria

Colon Bacillus

Antibacterial Activity Value Greater than 2.0

Staphylococcus Aureus

*Antibacterial Activity Value (R) = Ut- At ≧ 2.0 Ut: Average number of living bacteria (1㎠) on standard STRATAFLEX after 24 hours At: Average number of living bacteria (1㎠) on Anti-Bacterial STRATAFLEX after 24 hours