F or decades, lockout/tagout (LOTO) has been one of OSHA’s most frequently cited standards, and for good reason. The purpose is simple: ensure machinery and equip- ment cannot unexpectedly energize while employees are servicing or maintaining it. But as backup power systems be- come more sophisticated, so do the challenges of controlling hazardous energy. Today’s generators are often connect- ed to remote monitoring platforms, automatic transfer switches (ATS), building management systems, and cloud-based controls. While these technologies improve reliability and reduce downtime, they also intro- duce new risks that traditional LOTO procedures may not adequately ad- dress. Years ago, isolating a generator often meant opening a disconnect, apply- ing locks and tags, and verifying the equipment was de-energized. Today, the picture is much more complex. A technician servicing a generator may also need to consider: • Automatic transfer switches that can initiate system changes. The New Reality of Hazardous Energy • Remote start commands issued from a supervisory control sys- tem. • Building management systems in- tegrated with emergency power. • Battery backup systems supplying control circuits. • Multiple utility and generator pow- er sources. • Parallel generator systems with interconnected equipment.

The result is that hazardous energy may exist in places employees do not immediately recognize. Why OSHA Cares, and Why the Right Standard Matters When OSHA investigates an electri- cal incident, one of the first questions is whether the employer had an en- ergy control procedure that reflected how the equipment actually operates. A generic LOTO procedure that fails to address remote controls, stored electrical energy, or multiple power sources may not satisfy OSHA’s ex- pectations. It’s also worth remembering that not every generator or switchgear task falls neatly under the general LOTO standard. Depending on voltage lev- els and the scope of work, servicing may instead be governed by more specific standards. Before finalizing a procedure, service companies should confirm which standard applies to the specific task at hand. The energy control principles below apply broad- ly, but the exact regulatory require- ments can shift depending on that determination. OSHA inspectors typically want to know: • Have all energy sources been identified? • Can the equipment be started re- motely? • Have control circuits been isolat- ed? • Was the absence of voltage veri- fied? • Were employees trained on the actual configuration of the sys- tem? These aren’t pulled from a specific OSHA checklist. They’re the kinds of questions a compliance officer will

Karen F.Tynan Shareholder, Ogletree Deakins

Robert C. Rodriguez Shareholder, Ogletree Deakins

14 | Fall 2026 POWERLINE

Made with FlippingBook flipbook maker