Figure 2 shows the general location and nomenclature of the blades in a wind turbine generator. When the rotor is locked in the “Y” position, with the cover for lifting bracket (1) facing upward, then:

For additional designs Blade A (2) is positioned to the left (counterclockwise) of the cover for the lifting bracket (1). Blade B (3) is positioned facing down toward the tower and Blade C (4) is positioned to the right of the cover for the lifting bracket. Blade A (3) is positioned facing down toward the tower of the cover for the hatchway (1). Blade B (2) is positioned to the left (counterclockwise) and Blade C (4) is positioned to the right of the hatchway.

Number

Name Blade 1

Blade 2

1

Cover for lifting bracket

Hatchway

2 3 4

Blade A Blade B Blade C

Blade B Blade A Blade C

Figure 2: Blade Nomenclature

Step by step work instruction

When performing energy isolation, if there is a discrepancy between this document and the Energy Isolation Procedure (EIP), then the EIP takes priority.

CAUTION

Hazard working at height. Not using the correct PPE can result in injury. Wear proper PPE according to work location

CAUTION

Hazard of dropped object. Not using the correct PPE can result in injury. Wear proper PPE according to work location

Global Wind Organisation / www.globalwindsafety.org

172 / 187