150m Rotary Laser Level Kit (TB-H2S4-LL-M150-R1)

Powering ON

The instrument can be used in either a Self-levelling Mode or Pendulum Locked Mode . Power-ON in the Self-Levelling Mode: In this mode, the laser level checks the horizontal position and automatically self-aligns within the self-levelling range of approx. ±3.5°. 1. Place the instrument on a hard and level surface. 2. If you use the tripod, stabilise it before mounting the instrument on it. 3. Rotate the Pendulum Lock/Unlock Switch 3 to the UNLOCKED position to activate the laser beam.

3

NOTE: If the instrument is tilted beyond its self-leveling limits (3.5°), it will not level and will emit a beeping sound indicating an error. Power-ON in the Pendulum Locked Mode: In a Pendulum Locked Mode, the self-levelling capability is disabled, and the laser level can be tilted to project a laser beam at an incline. Press the Power Button 2 for three seconds to activate the laser beam. IMPORTANT! In this mode, the Pendulum Lock/Unlock Switch 3 MUST ALWAYS be in the LOCKED position. NOTE: In any application where the instrument must be utilised in a tilted position, power it on in the Pendulum Locked Mode only.