D-Tech Rotary Steerable Operations Manual

Operations Manual

Lost Circulation Material (LCM) Exercise caution when running with LCM as it can cause premature tool issues with the RST control and steering sections. Certain flow paths on the RST can be plugged off with small cuttings and LCM material if the mixtures are not clean and added properly to the mud system. RST 475/500 RST 650/675/800/900 Max LCM Concentration lb/bbl (kg/l) 30 (0.13) 50 (0.19) Please refer to Appendix A for the recent D-Tech recommendations on LCM for further examples of LCM and concentrations for running with the system. The use of a PBL or bypass sub along with a dedicated Filter sub is recommended in all applications, where LCM may be used. Appendix A: LCM Recommendations

LCM Name

Description

Max recommended

Mixture of fibre, granules and flakes. Brown, white and grey in colour.

25 lbs / bbl. (71.3kg/m³) 25 lbs / bbl. (71.3kg/m3) 15 lbs / bbl. (42.8kg/m³)

Baro Seal

Baro Fibre

Natural cellulose fibre

Fibrous material which can block of steering body filter. Mix well before use. Fibrous material which can block steering body filter. Mix well before use. Worse if used in polymer-based muds

Cedar Fibre

8 lbs / bbl. (22.8kg/m³)

Cotton Seed Hulls

10lbs / bbl. (28.5kg/m³)

Plug git / Plug git P

Ground cedar fibre

5 lbs / bbl. (14.27kg/m³)

Plug git H

Ground hardwood

OPS-FIELD-001 | Rev. H

dtechdrilling.com | 58

Made with FlippingBook Digital Publishing Software