D-Tech Rotary Steerable Operations Manual

Operations Manual

RST PC Field Software

Not Required

PC software used for hydraulic calculations, downlinking, downlink training, and manual downlink verification.

http://dtechdrillingtechnical.com/software/dtech-field- software/publish.htm

Appendix C: Tool Specifications

D-Tech RST Specifications

RST475

RST500

RST650

RST675

HDT675 9

RST800

RST900

RST900 PLUS

RST1100

5 7 / 8 to 6½ (149.225 to 165.1)

6¾ (171.45)

7 7 / 8 (200.025)

9 7 / 8 to 10 8 (250.825 to 269.875) 5 /

16 to 18 1 / 8 (406.4 to 460.375)

8½ to 8¾ (215.9 to 222.25)

8½ to 8¾ (215.9 to 222.25)

12¼ to 12½ (311.15 to 317.5)

13½ (342.9)

Hole size, in. (mm)

11.5 (3.50) w/o stabilizer

11.5 (3.50) w/o stabilizer

15.637 (4.766) w/ stabilizer

13 (3.96) w/ stabilizer

13.09 (3.99) w/ stabilizer

14.91 (4.54) w/o stabilizer

12.87 (3.92) w/o stabilizer

12.87 (3.92) w/o stabilizer

15.55 (4.74) w/o stabilizer

Tool length, ft (m)

Nominal OD, in. (mm)

4.75 (120.65)

5.00 (127)

6.50 (165.10)

6.75 (171.45)

6.75 (171.45)

9 (228.6)

9 (228.6)

9 (228.6)

9 (228.6)

400,000 (1,800,000)

400,000 (1,800,000)

1,100,000 (4,900,000)

1,200,000 (5,300,000)

1,200,000 (5,300,000)

1,400,000 (6,200,000)

1,500,000 (6,700,000)

1,500,000 (6,700,000)

1,500,000 (6,700,000)

Max overpull, lbf (N)

8,000 10,846)

8,500 (11,525)

16,000 (21,693)

16,000 (21,693)

20,000 (27,116)

55,000 (74,570)

55,000 (74,570)

65,000 (88,128)

65,000 (88,128)

Max torque-at-bit, ft-lbf (N·m)

Max weight-on-bit, lbf (N)

Drill bit limited

Drill bit limited

Drill bit limited

Drill bit limited

Drill bit limited

Drill bit limited

Drill bit limited

Drill bit limited

Drill bit limited

Bit connection, in.

3½ Reg

3½ Reg

4½ Reg

4½ Reg

4½ Reg

6 5 / 8 Reg

6 5 / 8 Reg

6 5 / 8 Reg

7 5 / 8 Reg

Max DLS passthrough - nonrotating (rotating), °/100 ft (°/30 m) 1

25 (15)

25 (15)

16 (10)

16 (10)

20 (14)

10 (7)

10 (7)

10 (7)

10 (7)

170 to 400 (643 to 1,514)

170 to 400 (643 to 1,514)

300 to 670 (1,135 to 2,540)

300 to 670 (1,135 to 2,540)

300 to 670 (1,135 to 2,540)

410 to 1,200 (1,552 to 4,550)

410 to 1,200 (1,552 to 4,550)

410 to 1,200 (1,552 to 4,550)

410 to 1,200 (1,552 to 4,550)

Flow range, gal/min (L/min) 2

Max mud density, lbm/gal US (kg/L) 3 20 (2.39)

20 (2.39)

20 (2.39)

20 (2.39)

20 (2.39)

20 (2.39)

20 (2.39)

20 (2.39)

20 (2.39)

Material dependent

Material dependent

Material dependent

Material dependent

Material dependent

Material dependent

Material dependent

Material dependent

Material dependent

Chlorides, ppm 4

Max LCM concentration, lbm/bbl (kg/L) 5

30 (0.13)

30 (0.13)

50 (0.19)

50 (0.19)

50 (0.19)

50 (0.19)

50 (0.19)

50 (0.19)

50 (0.19)

9 to 12

9 to 12

9 to 12

9 to 12

9 to 12

9 to 12

9 to 12

9 to 12

9 to 12

pH 6

Max sand content, %

1

1

1

1

1

1

1

1

1

Max pressure, psi (MPa)

20,000 (137.9)

20,000 (137.9)

20,000 (137.9)

20,000 (137.9)

20,000 (137.9)

20,000 (137.9)

20,000 (137.9)

20,000 (137.9)

20,000 (137.9)

Max temperature, °F (°C)

302 (150)

302 (150)

302 (150)

302 (150)

302 (150)

302 (150)

302 (150)

302 (150)

302 (150)

Max operational rev/min

330

330

330

330

400

230

230

230

190

Max DLS capability, °/100 ft (°/30 m) 7

8

8

8

8

12

5

5

5

3

3½ IF (NC38) or XT39 3½ IF (NC38) or XT39 4½ IF (NC50)

4½ IF (NC50)

4½ IF (NC50)

6 5 / 8 Reg

6 5 / 8 Reg

6 5 / 8 Reg

7 5 / 8 Reg

Up-hole/top connection, in. 8

¹ Contact your D-Tech rep if your DLS exceeds what is provided. ² Dependent on mud density. 3 Dependent on mud properties 4 >50,000 ppm requires the RST to be surface-flushed/externally cleaned with freshwater post-run. High-chloride resistant material options available on request, contact D-Tech.

5 Subject to the type of lost circulation material (LCM), medium-sized LCM. For specific materials, contact D-Tech. 6 For silicate fluid systems, contact D-Tech. 7 Dependent on application, formation, bit design, run parameter, etc. 8 Alternative top connections are available on request. 9 HDT BHA configuration dependent on application requirements.

© D-Tech, 2023. All rights reserved. DT0001 / 09/23 www.dtechdrilling.com 1. Contact your local D-Tech rep if DLS exceeds what is provided 2. Dependant on mud density 3. Dependant on mud properties 4. >50,000 ppm requires surface flushing/external cleaning of RST WITH Fresh water post run. High Chloride resistant material options available. Contact D-Tech 5. Subject to type of Lost Circulation Material (LCM), medium sized LCM. For specific materials contact D-Tech. 6. D-Tech should be contacted for Silicate fluid systems 7. Dependant on application, formation, bit design, run parameters etc. 8. Alternative top connections are available on request. 9. HDT BHA configuration dependent on application requirements

OPS-FIELD-001 | Rev. H

dtechdrilling.com | 60

Made with FlippingBook Digital Publishing Software