PAAS SB V4.1

Industrial Grey PVC-U Pipe And Fittings Pneumatic Actuated P -H Valves

Pneumatic Actuated Valve Overview

Pneumatic Actuated valves selection advice:

1. Decide if Manual Override is required  Manual Override allows the valve to be manually opened or closed if air supply is unavailable 2. Select valve size:  Manual Override: 1/2” up to 2”

 Without Manual Override: 1/2” up to 4” 2. Select Ball Valve Seals: EPDM or FPM

3. Actuator Style: FSC or FSO or DA  FSC: Fail Safe Close : Springs will close the valve when air pilot valve air supply turned off  FSO: Fail Safe Open : Springs will open the valve when air pilot valve air supply is turned off  DA: Double Acting : No Springs in Actuator valve will stay in last position when air pilot valve is turned off. 4. Are Limit Switches Required, if so select integrated or external mount options  Integrated Limit Switches: mounted between valve & actuator (recommended when using manual override)  External Limit Switches: mounted atop the actuator 5. Is a Pilot Solenoid Valve Required  If using a FSC / FSO Actuator a PV94 (3/2) Solenoid or a MNL532 (5/2) Solenoid can be used  If using a DA Actuator only a MNL532 (5/2) Solenoid can be used

Solenoid/Pilot Valves - PV 94 (3/2)

 Suitable for FSC & FSO Actuators  Solenoid Valve is direct mounted to actuator

Unit

24V D/C 24V A/C 110V A/C 230V A/C

199 190 498 199 190 499 199 190 500 199 190 501

Solenoid/Pilot Valves - MNL532 (5/2) / (3/2)

 Suitable for FSC , FSO and DA Actuators  Features: silencer and throttle control  Requires namur plate to mount actuator Ball valve size 1/2” - 2” namur code: 199 190 378 Ball valve size 2.5” - 4” namur code: 199 190 275

Unit

24V D/C 24V A/C 110V A/C 230V A/C

199 190 357 199 190 358 199 190 359 199 190 360

124 PAAS Source Book

www.paas.com.au

V 4.1