PAAS SB V4.1

Industrial Grey PVC-U Pipe And Fittings Flow

Paddlewheel Flow Sensor Type 2537

 Type 2537 is a stand alone unit that does not use a transmitter, it has a 4-20mA  There is no display on this sensor and therefore must be used in with your PLC or Scada Program

Paddlewheel Flow Sensor Type 2537

Technical Information: Pressure Temperature Graph

Specifications  0.1-6 m/s (0.3 to 20 ft/s)  DN15-DN200 (1/2 to 8 in.)

 PP 12.5 bar @ 20°C (181 psi @ 68° F)  PVDF 14 bar @ 20 °C (203 psi @ 68° F)  4-20 mA, digital (S³L), flow switch or pulse outputs (based on part number)

Applications:  Chemical Production  Process Flow Monitoring

 Reverse Osmosis  Fume Scrubbers  Demineralization/Regeneration

 Pump Protection  Filtration systems  Pure Water Production  Cooling Towers

Overview: Paddlewheel Flow Sensor Type 2537

The Signet 2537 Flow Sensor is the next generation in fluid measurement technology from the inventor of the original paddlewheel flow meter. This sensor is an enhancement on what’s already an industry standard. It has the added functionality of various output options including flow switch, pulse divider, digital (S3L) or 4 to 20 mA. Additionally, it offers low flow, low power and high resolution and can be configured on-site directly through the built-in user interface.

Installation is simple because the Signet 2537 utilises the same fittings as the popular Signet 515 and 2536 Paddlewheel Sensors, and fits into pipe sizes ranging from DN15 to DN200 (½ to 8 in.). Available in Polypropylene and PVDF, it is ideal for a variety of applications including chemical process- ing, water and wastewater monitoring and scrubber control.

194 PAAS Source Book

www.paas.com.au

V 4.1

Made with FlippingBook - Online catalogs