Victron Energy Centaur Chargers
Centaur Battery Chargers The Centaur range of battery chargers have been designed to be a true world-wide product. Aluminium epoxy powder coated cases with drip shield and stainless steel fixings withstand the rigours of an adverse environment: heat, humidity and salt air. Circuit boards are protected with an acrylic coating for maximum corrosion resistance. Temperature sensors ensure that power components will always operate within specified limits, if needed by automatic reduction of output current under extreme environmental conditions. Universal compliance and input/ output specifications are cornerstone characteristics from the established Dutch manufacturer.
Features: • 3 Stage charging • 3 independent outputs
• Universal input • 12V 20A - 100A • 24V 16A - 60A
Related Products:
Battery Monitor
Battery Alarm
12/30 24/16
12/60 24/30
12/80 24/40
12/100 24/60
Centaur Charger
12/20
12/40
12/50
Input Voltage (V AC) Input Voltage (V DC) Input Frequency (Hz)
90 - 265 90 - 400
45 - 65
Power Factor
1
Charge Voltage ‘Absorption’ (V DC)
14.3 / 28.5 (1)
Output Banks
3
Charge Current (A) (2) Total Output Ammeter Charge Characteristic Recommended Battery Capacity (Ah) Temperature Sensor
20
30 / 16
40
50
60 / 30
80 / 40
100 / 60
Yes
IUoU (Three Stage Charging)
120 - 300 45 - 150
240 - 600 120 - 300
320 - 800 160 - 400
400 - 1000 240 - 600
80 - 200
160 - 400
200 - 500
Internal - 2mV / °C (- 1mV / °F) Per Cell Yes, Temperature and Current Controlled Fan Output Short Circuit, Over Temperature
Forced Cooling
Protection
Operating Temp. Range
-20 to 60°C (0 - 140°F)
Ignition Protected
Yes
Humidity (Non Condensing)
Max 95%
Enclosure
Material & Colour
Aluminium (Blue RAL 5012)
Battery - Connection AC - Connection Protection Category
M6 Studs
M6 Studs
M8 Studs
M8 Studs
M8 Studs
M8 Studs
M8 Studs
Screw - clamp 4 mm² (AWG 6)
IP 20 5 (11)
Weight Kg (lbs)
3.8 (8.4)
3.8 (8.4)
5 (11)
5 (11)
12 (26)
12 (26)
Dimensions H x W x D in mm (H x W x D in Inches)
355 x 215 x 110 (14.0 x 8.5 x 4.3)
355 x 215 x110 (14.0 x 8.5 x 4.3)
426 x 239 x135 (16.8 x 9.4 x 5.3)
426 x 239 x 135 (16.8 x 9.4 x 5.3)
426 x 239 x 135 (16.8 x 9.4 x 5.3)
505 x 255 x 130 (19.9 x 10.0 x 5.2)
505 x 255 x 130 (19.9 x 10.0 x 5.2)
Standards
Safety
EN 60335 - 1, EN 60335 - 2 - 29, UL 1236
Emissions Immunity Automotive Directive
EN 55014 - 1, EN 61000 - 3 - 2
EN 55014 - 2, EN 61000 - 3 - 3 1) Standard setting. Optimum charge / float voltages for flooded Lead - acid, Gel - Cell or AGM batteries selectable by dip switch 2) Up to 40°C (100°F) ambient. Output will reduce to approximately 80% of nominal at 50°C (120°F) and 60% of nominal at 60°C (140°F)
Veloris. The Battery Partner.
132