Victron Energy Skylla Chargers
Skylla-IP65 Battery Charger •
Skylla-IP65 (1+1): two outputs to charge 2 battery banks The Skylla-IP65 (1+1) features 2 isolated outputs. The second output, limited to approximately 3 A and with a slightly lower output voltage, is intended to top up a starter battery. • The Skylla-IP65 (3) features 3 isolated outputs. All outputs can supply the full rated output current. • IP65 protection Steel epoxy powder coated case. Withstands the rigours of an adverse environment: heat, humidity and salt air. Circuit boards are protected with an acrylic coating for maximum corrosion resistance. Temperature sensors ensure that power components will always operate within specified limits, if needed by automatic reduction of output current under extreme environmental conditions. • LCD display. For status monitoring and to easily adapt the charge algorithm to a particular battery and its conditions of use. • CAN-bus interface (NMEA2000). To connect to a CAN-bus network, to a Skylla-i Control panel or to the Colour Control digital display. • Synchronised parallel operation. Several chargers can be connected in parallel and synchronised with help of the CAN-bus interface. This is achieved by simply interconnecting the chargers with RJ45 UTP-cables. •
The right amount of charge for a lead-acid battery: variable absorption time .When only shallow discharges occur the absorption time is kept short in order to prevent overcharging of the battery. After a deep discharge the absorption time is automatically increased to make sure that the battery is completely recharged.
Skylla-IP65
12/70 (1+1)
12/70 (3)
24/35 (1+1)
24/35 (3)
Input voltage (VAC)
120/230 V 90-265 V
Input voltage range (VAC)
Maximum AC input current @ 100 VAC
12 A
Frequency (Hz)
45-65 Hz
Power factor
0.98
Charge voltage 'absorption' (1)
14.4 V 13.8 V 13.2 V
28.8 V 27.6 V 26.4 V
Charge voltage 'float' Charge voltage ‘storage’
3 x 70A (max total output: 70 A)
3 x 35 A (max total output: 30 A)
Charge current (2)
70 A
35 A
Charge current starter batt. (A)
3 A
-
3 A
-
Charge algorithm Battery capacity
7 stage adaptive
350-700 Ah
150-350 Ah
Charge algorithm, Li-Ion
3 stage, with on-off control or CAN bus control
Temperature sensor
Yes Yes
Can be used as power supply
Remote on-off port
Yes (can be connected to a Li-Ion BMS)
CAN bus communication port (VE.Can)
Two RJ45 connectors, NMEA2000 protocol, not isolated
Synchronised parallel operation
Yes, with VE.Can
Alarm relay
DPST AC rating: 240VAC/4A DC rating: 4A up to 35VDC, 1A up to 60VDC
Forced cooling
Yes (internal air circulation)
Protection
Battery reverse polarity (fuse) Output short circuit Over temperature
Operating temp. range
-20 to 60°C (Full output current up to 40°C)
Humidity (non-condensing)
max 95%
Enclosure
Material & Colour
Steel (blue RAL 5012)
Battery - Connection 230V AC - Connection Protection category
M6 bolts
screw-clamp 6mm² (AWG 10)
IP65
Weight (Kg)
6kg (14 lbs)
Dimensions (mm) H x W x D
401 x 265 x 151 mm (16 x 10.5 x 6 inch)
Standards
Safety
EN 60335-1, EN 60335-2-29
Emission Immunity
EN 55014-1, EN 61000-6-3, EN 61000-3-2
EN 55014-2, EN 61000-6-1, EN 61000-6-2, EN 61000-3-3
Veloris. The Battery Partner.