Veloris Comprehensive Catalogue 2025 (v1)

Victron Energy Skylla Chargers

Skylla-i Battery Chargers Skylla-i (1+1): two outputs to charge 2 battery banks

Important features: • Synchronised parallel operation • The right amount of charge for a lead-acid battery: variable absorption time • Preventing damage due to excessive gassing: the BatterySafe mode • Less maintenance and ageing when the battery is not in use: the Storage mode • To increase battery life: temperature compensation • Battery voltage sense • Suitable for AC and DC supply (AC-DC and DC- DC operation) • Li-Ion (LiFePO4) ready

The Skylla-i (1+1) features 2 isolated outputs. The second output, limited to approximately 4 A and with a slightly lower output voltage, is intended to top up a starter battery. Skylla-i (3): three full current outputs to charge 3 battery banks The Skylla-i (3) features 3 isolated outputs. All outputs can supply the full rated output Aluminium epoxy powder coated cases with drip shield and stainless steel fixings. Circuit boards are protected with an acrylic coating for maximum corrosion resistance. Flexible Next to a CAN bus (NMEA2000) interface, a rotary switch, DIP switches and potentiometers are available to adapt the charge algorithm to a particular battery and its conditions of use. current. Rugged

Skylla-i

24/80 (1+1)

24/80 (3)

24/100 (1+1)

24/100 (3)

Input Voltage (V AC)

230

Input Voltage Range (V AC) Input Voltage Range (V DC)

185-265 180-350

Maximum AC input current @ 180 VAC

16 A

20 A

Frequency (Hz) Power Factor

45-65

0.98 28.8 27.6 26.4

Charge Voltage ‘absorption’ (V DC)

Charge Voltage ‘float’

Charge voltage ‘storage’ (VDC)

Charge Current House Batt. (A) (2)

80

3 x 80A (max total output: 80A)

100

3 x 100A (max total output: 100A)

Charge Current Starter Batt (A)

4

-

4

-

Charge Characteristic Battery Capacity (Ah) Charge Curve, Li-Ion Temperature Sensor

7 Stage Adaptive

400-800

500-1000

3 stage, with on-off control or CAN bus control

✓ ✓

Can be used as a power supply

Remote on-off port

Yes (can be connected to a Li-Ion BMS)

Forced Cooling Protection (1)

Battery reverse polarity (fuse) Output short circuit Over temperature

Operating Temp. Range Humidity (non-condensing)

-20°C to 60°C (Full output current up to 40°C)

Max 95%

Enclosure

Material & Colour Battery-Connection 230V AC-Connection Protection Category

Aluminium (Blue RAL 5012)

M8 Bolts

Screw-Clamp 10mm² (AWG 7)

IP21

Weight kg (lbs)

7 (16)

Dimensions (mm) H x W x D

405 x 250 x 150

Standards

Safety

EN 60335 - 1, EN 60335 - 2 - 29

Emission Immunity

EN 55014 -1, EN 61000 - 6-3, EN 61000 - 3-2

EN 55014 - 2, EN 61000 - 3 - 3 EN 610006-1, EN 61000-6-2

1) Protection

a. Output short circuit b. Battery reverse polarity detection c. Battery Voltage too high d. Temperature too high 2) Up to 40°C (100°F) ambient

Product Catalogue.

135