Orion-Tr Smart DC-DC charger non- isolated 360/400 Watt with 3-stage battery charge algorithm The Orion-Tr Smart DC-DC charger non-isolated is a professional DC to DC adaptive 3-stage charger with built-in Bluetooth. Any Bluetooth enabled smart phone, tablet or other device can be used to monitor, to change settings and to update the charger when new software features become available. Features • Bluetooth Smart enabled • Fully programmable • Adaptive 3-stage charge algorithm
Orion-Tr Smart non-isolated 12/12-30
• Remote on-off • IP43 protection
Orion-Tr Smart Chargers non-isolated 360 - 400 Watt
12/12-30 (360 W)
12/24-15 (360 W)
24/12-30 (360 W)
24/24-17 (400 W)
10-17 V
10-17 V
20-35 V
20-35 V
Input voltage range (1) Under voltage shut down Under voltage restart Nominal output voltage Output voltage adjust range Output voltage tolerance
7 V
7 V
14 V 15 V
14 V 15 V
7,5 V
7,5 V
12,2 V
24,2 V
12,2 V
24,2 V
10-15 V
20-30 V
10-15 V
20-30 V
+/- 0,2 V 2 mV rms
Output noise
Cont. output current at nominal output voltage and 40 °C Maximum output current (10 s) at nominal output voltage minus 20%
30 A
15 A
30 A
17 A
40 A
25 A
45 A
25 A
Short circuit output current Cont. output power at 25 °C Cont. output power at 40 °C
60 A
40 A
60 A
40 A
430 W 360 W
430 W 360 W
430 W 360 W
480 W 400 W
Efficiency
87 %
88 %
88 %
89 %
No load input current
< 80 mA
< 100 mA < 100 mA
< 80 mA
Standby current
Less than 1 mA
Operating temperature range
-20 to +55 °C (derate 3 % per °C above 40 °C)
Humidity
Max. 95 % non-condensing
DC connection
Screw terminals 16 mm² (AWG6)
Maximum cable cross-section
Weight
12 V input and/or 12 V output models: 1,8 kg (3 lb) Other models: 1,6 kg (3.5 lb)
Dimensions H x W x D Protection category
130 x 186 x 80 mm (5.1 x 7.3 x 3.2 inch)
IP43 ( electronic components ), IP2 2 (connection area)
Standards:
Safety
EN 60950
Emission Immunity
EN 61000-6-3, EN 55014-1
EN 61000-6-2, EN 61000-6-1, EN 55014-2
Automotive Directive
ECE R10-5
1) If set to nominal or lower than nominal, the output voltage will remain stable within the specified input voltage range (buck-boost function). If the output voltage is set higher than nominal by a certain percentage, the minimum input voltage at which the output voltage remains stable (does not decrease) increases by the same percentage. Note 1: The VictronConnect App will not display current in or current out. Note 2: The Orion-Tr Smart is not equipped with a VE.Direct port.