KCJ - CAPTURE JET™ VENTILATED CEILING
With low-velocity makeup air
Overview:
Features: • Compliant design: Halton Capture Jet ventilated ceilings comply with AS1668.2 and are designed to proven and tested standards. • Efficient: Capture Jet™ technology uses controlled angled and vertical air curtains to contain the exhaust air and move it toward the flters for effcient removal. • Effective: Halton’s KSA flters use cyclonic action to effciently separate contaminant particles. Independent tests verify that 95% of particles (10µm and above) are removed. • Safe: Halton’s ventilated ceilings have enclosed exhaust plenums and KSA flters that are UL1046 certifed to prevent the spread of flames from the kitchen into the exhaust plenum and duct. • Healthy: KCJ ventilated ceilings provide an open design kitchen work environment for improved health and well-being. Halton ventilated ceilings are designed for use in open commercial kitchens, production kitchens and show kitchens. The combination of Capture Jet™ and the provision for make-up air through the ceiling’s face at low velocity helps capture and contain the heat load with lower exhaust airflow. Halton KCJ ventilated ceilings can be installed from 2300-3000 above floor level to provide a healthy open kitchen environment.
Typical Section:
5
°C
*For dimensions refer to project drawing
Capture Jet™ technology Up to 40%
Cyclonic filter 95% efficient on 10um and above particles
T.A.B.™ technology Quick airflow rates measurement
reduction in airflow rates
Laminar flow supply Better capture and comfort
Recommended Combinations:
Halton Culinary Light Kitchen specific LED based lighting system (KCJ Skyline)
Built-in Fire Suppression Engineered & pre-installed from factory
M.A.R.V.E.L. Extend airflow reduction to up to 64%
ALLIED MEMBER
ALLIED MEMBER
R
R
Typical Specification Text:
Kitchen ventilated ceiling shall comply with AS1668.2 2012. Constructed from 1.2 mm AISI 304 Satin fnish with fully welded exhaust plenum. The ventilated ceiling shall be supplied complete with Capture Jet™ technology, high effciency UL1046 Certifed Cyclonic Filters (KSA) fully welded exhaust plenums with pressure measurement points, exhaust and supply air adjustment dampers, and flush light fttings to provide minimum 500 lux at the cooking surface. The size shall be as indicated in the drawings. The ceiling will be designed to save energy and capture effciency will be calculated using convective heat calculations methods.
19
Made with FlippingBook - Online Brochure Maker