maxon Product Range 2024/25

ENX 22 EASY INT Encoder ∅ 22 mm, 1...1024 CPT / 4096 steps, Single Turn Sterilizable, integrated into motor

Key data

EASY incremental differential

EASY Absolute

Number of channels Max. counts per turn Steps per turn Resolution (bit single turn) Encoder length L Ambient temperature

3 1024

4096 12

mm -1.5 (integrated into motor)

-1.5 (integrated into motor)

°C

-40…+125

-40…+125

Weight

g

<5

<5

Selection criteria

EASY incremental differential

EASY Absolute

Speed and rotation direction detection Speed and position control Compact and robust design

High resolution Cost effective

suitable

suitable to a limited extent

not suitable

Specifications Supply voltage Vcc Typical current draw Max. operating frequency

EASY incremental differential

EASY Absolute

V

5 ±0.5

5 ±0.5

mA kHz rpm

22

22

4000 200 000

Max. Speed Connector 2

200 000

10-pin 2.54 mm multipoint connector (IEC/EN 60603-13 / DIN41651) cable AWG 26 Pin 1 not connected

without connector cable AWG 26 green Data black V CC brown GND yellow CLK

10

9

2

Pin 2 (black) V CC Pin 3 (brown) GND Pin 4 Pin 5 (red) channel A Pin 6 (orange) channel A Pin 7 (yellow) channel B Pin 8 (green) channel B Pin 9 (blue) channel I Pin 10 (violet) channel I

1

not connected

Output signal: EIA-Standard RS 422 Output current per channel: ± 20 mA

Output signal: CMOS compatible Output current per channel + 20 mA

EC motor ECX SPEED 22 M ECX SPEED 22 L ECX TORQUE 22 M ECX TORQUE 22 L ECX TORQUE 22 XL Configuration Counts per turn 1 Signalprotokoll Cable length Electric connection modular system

EASY incremental differential

EASY Absolute

1…1024

BiSS-C, SSI 200, 500

mm

200, 500

cable length/pin connection/connector

Page Sterilization information

Notes

¹ maxon controllers require a resolution of at least 16 counts per turn and commutation signals. 2 H1, index and angle zero are aligned with angle commutation zero (see p. 64).

Typically 1000 autoclave cycles Sterilization with steam Temperature Compression pressure up to

222–225 226–229

239 240 241

+134 ± 4 °C 2.3 bar 18 minutes 100%

Rel. humidity Cycle length

The connector is not sterilizable and needs to be removed first.

Further technical details can be found in the product information in the online shop under Downloads.



514 maxon sensor 

© 2024 maxon. All rights reserved. August edition. Subject to change.

Made with FlippingBook Publishing Software