Thermal Performance | 8480A Series

Combustion air preheat vs. burner capacity vs. radiant tube exhaust temperature+ in degrees Fahrenheit*

Burner Capacity

Radiant Tube Exhaust Temperature

Recuperator

Sections

°F

( Btu/h HHV)

1,200

1,400

1,600

1,800

2,000

4X 4X 4X 3X 3X 3X 4X 4X 3X 3X

800,000 600,000 400,000 800,000 600,000 400,000 600,000 400,000 600,000 400,000

426 457 507 390 420 468 474 535 435 496

509 547 606 465 502 560 568 640 522 594

583 630 702 529 575 647 656 743 599 688

632 694 784 561 623 716 725 832 651 765

699 758 853 664 691 780 785 910

8480A-700

8480A-600

715

824

Combustion air preheat vs. burner capacity vs. radiant tube exhaust temperature+ in degrees Celsius*

( kW LHV) Burner Capacity

Radiant Tube Exhaust Temperature

Recuperator

Sections

°C

650 219 236 264 199 216 242 246 279 224 258

760 265 286 319 241 261 293 298 338 272 312

871 306 332 372 276 302 342 347 395 315 364

982 333 368 418 294 328 380 385 444 344 407

1,093

4X 4X 4X 3X 3X 3X 4X 4X 3X 3X

212 159 106 212 159 106 159 106 159 106

371

403 456

8480A-700

351

366 416 418 488 379 440

8480A-600

* Based on 10% XSA operation + See North American Handbook Supplement #290, Estimating Radiant Tube Exhaust Temperature.