Combustion Catalog | Fives North American

Product Overview |4659 Gas Tunnel Burner

at 12 o'clock for the pilot and ¾ " fpt holes at 1 and 2 o'clock for an observation port and flame detector. North American strongly recommends the use of interrupted pilots with burners monitored by flame detectors. UV detectors are compatible with these burners. Flame rods require that a ground rod be added to the burner nozzle. This option is available at an extra cost. Contact Fives North American Combustion, Inc. for the proper part number when ordering this option .

4659 Premix Gas Tunnel Burners consist of a burner nozzle, mounting plate and tile. These burners operate on an air-gas mixture as supplied by North American 3065 Aspirator Mixers or similar mixing devices. When sealed, they prevent air infiltration and may be used on furnaces requiring controlled atmospheres and positive or negative chamber pressure s. The burner tiles are rated at 3200°F maximum operating temperature. The burner mounting plate includes a slip-fit hole

Combustion Air Capacities scfh (Btu/h HHV = scfh × 100)

Burner

Mixture pressure in inches of water

designation

1

1.5

2.5

5

7

8

12

4659-1-A 4659-1-B 4659-2-A 4659-2-B 4659-2-C 4659-2-D 4659-3-A 4659-3-B 4659-4-A 4659-4-B 4659-4-C 4659-5-A 4659-5-B 4659-6-A 4659-6-B 4659-6-C 4659-7-A 4659-7-B 4659-7-C

350 440 560 650 780 880 980

430 540 680 800 960

560 700 880

790 990

920

990

1210 1520 1930 2240 2680 3020 3380 4120 5150 6550 7050 8450

1160 1480 1720 2060 2320 2590 3170 3960 5000 5400 6500 7650 8450

1240 1580 1840 2190 2480 2760 3380 4240 5350 5800 6900 8200 9000

1260 1460 1750 1980 2200 2690 3360 4270 4610 5500 6500 7200 8650 9550

1030 1230 1390 1550 1900 2380 3010 3240 3880 4600 5050 6100 6700 7500 9500

1080 1200 1460 1830 2320 2500 3000 3540 3910 4700 5150 5800 7350 8600

1200 1500 1900 2050 2450 2900 3200 3850 4250 4750 6000 7050

10000 11000 13200 14600 17000 20600 24200

10200 11200 12600 15800 18600

10800 12000 13400 16900 19800

10600 13400 15800

11100

Minimum mixture pressure must be at least 0.25"w.c. above furnace pressure when burning natural gas.

4659-3-B Flame at 300,000 Btu/h HHV.

WARNING: Situations dangerous to personnel and property may exist with the operation and maintenance of any combustion equipment. The presence of fuels, oxidants, hot and cold combustion products, hot surfaces, electrical power in control and ignition circuits, etc., are inherent with any combustion application. Components in combustion systems may exceed 160°F (71°C) surface temperatures and present hot surface contact hazard. Fives North American Combustion, Inc. suggests the use of combustion systems that are in compliance with all Safety Codes, Standards, Regulations and Directives; and care in operation.

Bulletin 4659 Page 2

Made with FlippingBook flipbook maker