ENGINEERING DATA Burner Capacities with 100% air through burner j

Blast tip burner designantion

"w.c. mbar

0.5 1.2

1.0 2.5

4.0 10.0

5.0 12.5

6.0 14.9

8.0 19.9

10.0 24.9

Btu/h HHV

7000

10 000

20 000

22 000

24 000

28 000

31 000

kW LHV

1.85

2.64 100

5.28 200

5.81 220

6.34 240

7.39 280

8.18 310

4624-02

Air Flow scfh

70

(Nm 3 /h)

(1.87)

(2.67)

(5.35)

(5.88)

(6.42)

(7.48)

(8.29)

Btu/h HHV

11 000

15 000

30 000

34 000

37 000

43 000

48 000

kW LHV

2.90

3.96 150

7.92 300

8.98 340

9.77 370

11.35

12.67

4624-01

Air Flow scfh

110

430

480

(Nm 3 /h)

(2.90)

(3.96)

(7.92)

(8.98)

(9.77)

(11.35)

(12.67)

Typical stoichiometric ratio by volume for air/natural gas premix = 10:1. For air/propane premix = 24:1.

j Burners can be run with less than 100% primary air (rich) if sufficient secondary airis available. If operating with 90% primary air, multiply capacities above by 1.11; multiply by 1.22 for 80% primary air. The obsolete 4622 burners were the same capacity as the 4624.

∆ P 1 ∆ P 2 √

Selection Example: Select blast tips and an aspirator mixer for 148 000 Btu/h HHV release on natural gas. Tips are to operate over 3:1 turndown on stoichiometric ratio. Minimum permissible mixture pressure is 0.25"w.c. (0.62 mbar), therefore required high fire mixture pressure to obtain 3:1 turn- down is based on the following equation: If the -02 tips are selected, 10 are required for the desired capac- ity (10 X 14,800 Btu/h HHV = 148,000 Btu/h HHV). From Bulletin 3065, a 3065-3-11 Mixer, with a capacity of 1550 scfh air at 2.5"w.c. mixture pressure will suffice. This mixer has a 1½“ pipe size outlet; so fabricate the blast tip manifold from 1½” pipe

2 × ∆ P

∴ ∆ P 1 = (Turndown Ratio)

T urndown Ratio =

2

0.25"w.c. × 3 2 = 2.25"w.c.

At this pressure, -02 tip capacity can be calculated as follows:

√ ∆ P 2 ∆ P 1

Q 2 = Q 1 Q 2 for -02 tip = 22 000 at 5"wc (from capacity chart below) 22 000 × = 14 800 Btu/h HHV.

√ 2.25" 5"

5" √

2.25"

Q 2 for -01 tip = 34 000 ×

= 22 800 Btu/h HVV.

A NPT

A NPT

E

E

B

C

B

C

F

F

4624

4622

D

D

Blast tip

dimensions in inches (mm)

weight oz (kg) 1.8 (0.05) 2.3 (0.07) 3.0 (0.09) 3.4 (0.10)

Open flow area

designation A NPT

B

C

D

E

F

inch2 0.085 0.131 0.085 0.131

mm2 (54.8) (84.5) (54.8) (84.5)

4622-02 4622-01 4624-02 4624-01

3/8 1/2 3/8 1/2

0.38 (9.5) 0.44 (11) 0.38 (9.5) 0.44 (11)

0.88 (22) 0.88 (22) 0.88 (22) 0.88 (22)

1.25 (32) 1.31 (33) 1.25 (32) 1.31 (33)

1.13 (29) 1.31 (33) 1.13 (29) 1.25 (32)

1.0 (25.4) 1.19 (30) 1.44 (37) 1.44 (37)

Note: the 4622 burners are now obsolete, replace with 4624

DIMENSIONS SHOWN ARE SUBJECT TO CHANGE. PLEASE OBTAIN CERTIFIED PRINTS FROM FIVES NORTH AMERICAN COMBUSTION, INC. IF SPACE LIMITATIONS OR OTHER CONSIDERATIONS MAKE EXACT DIMENSION(S) CRITICAL .