Sheet 4624 page 3

VERY SMALL PREMIX TIPS, 4029-03

Ø 1.00 (25.4)

For applications where a premix burner smaller than a 4624 is needed, consider the 4029-03. The open flow area is only 0.0334 inch² (21.5 mm²) which delivers about 1/3 the capacity of the 4624-02. This tip has a two-piece design. The body which includes the 1/4 " NPT threaded inlet connection is made from steel. The tile or “cap” is 304 stainless-steel. The highest mixture pressure that the tip will operate at is 10"w.c. (24.9 mbar), but like the 4624 the recommended inlet pressure is 4“w.c. (10 mbar). The flame is approximately 2 1/2 " (64 mm) long and can be difficult to see in a well-lit room until it warms up. 4029-03-M

1/4" NPT

0.44 (11)

4029-03-M

1.50 (38)

Dimensions inches (mm)

The 4029-03-M is a manually lit premix burner.

4029-03-E

4029-03-E

The 4029-03-E is spark ignited with an added 10mm spark plug connection for the included R240-2465 igniter .

2.88 (73)

Blast tip burner designantion

"w.c. mbar

0.5 1.2

1.0 2.5

4.0 10.0

5.0 12.5

6.0 14.9

8.0 19.9

10.0 24.9

Btu/h HHV

1900 0.50

2500 0.66

5300 1.40

5700 1.50

6000 1.58

6900 1.82

7300 1.93

kW LHV

4029-03-M 4029-03-E

Air Flow scfh

19

25

53

57

60

69

73

(Nm 3 /h)

(0.51)

(0.67)

(1.42)

(1.52)

(1.60)

(1.84)

(1.95)

Other Small Premix Burner Bulletins and Accessories See product details on bulletins and sheets listed below

4011 4011 Pilot Sets/4021 Pilot Tips 4018 High Pressure Gas Pilot Specifications 4027 Pilot Tips ( 3/4 " outlet with 1/2 " inlet) 8666 Testip

1122 Manual Butterfly Valves for Gas and Air 3065 North American Aspirator Air/Gas Mixers

3070 High Pressure Inspirators 7128 Air/Gas Ratio Regulators

WARNING: Situations dangerous to personnel and property may exist with the operation and maintenance of any combustion equipment. The presence of fuels, oxidants, hot and cold combustion products, hot surfaces, electrical power in control and ignition circuits, etc., are inherent with any combustion application. Components in combustion systems may exceed 160°F (71°C) surface temperatures and present hot surface contact hazard. Fives North American Combustion, Inc. suggests the use of combustion systems that are in compliance with all Safety Codes, Standards, Regulations and Directives; and care in operation.