Sheet 4624 page 3
VERY SMALL PREMIX TIPS, 4029-03
Ø 1.00 (25.4)
For applications where a premix burner smaller than a 4624 is needed, consider the 4029-03. The open flow area is only 0.0334 inch² (21.5 mm²) which delivers about 1/3 the capacity of the 4624-02. This tip has a two-piece design. The body which includes the 1/4 " NPT threaded inlet connection is made from steel. The tile or “cap” is 304 stainless-steel. The highest mixture pressure that the tip will operate at is 10"w.c. (24.9 mbar), but like the 4624 the recommended inlet pressure is 4“w.c. (10 mbar). The flame is approximately 2 1/2 " (64 mm) long and can be difficult to see in a well-lit room until it warms up. 4029-03-M
1/4" NPT
0.44 (11)
4029-03-M
1.50 (38)
Dimensions inches (mm)
The 4029-03-M is a manually lit premix burner.
4029-03-E
4029-03-E
The 4029-03-E is spark ignited with an added 10mm spark plug connection for the included R240-2465 igniter .
2.88 (73)
Blast tip burner designantion
"w.c. mbar
0.5 1.2
1.0 2.5
4.0 10.0
5.0 12.5
6.0 14.9
8.0 19.9
10.0 24.9
Btu/h HHV
1900 0.50
2500 0.66
5300 1.40
5700 1.50
6000 1.58
6900 1.82
7300 1.93
kW LHV
4029-03-M 4029-03-E
Air Flow scfh
19
25
53
57
60
69
73
(Nm 3 /h)
(0.51)
(0.67)
(1.42)
(1.52)
(1.60)
(1.84)
(1.95)
Other Small Premix Burner Bulletins and Accessories See product details on bulletins and sheets listed below
4011 4011 Pilot Sets/4021 Pilot Tips 4018 High Pressure Gas Pilot Specifications 4027 Pilot Tips ( 3/4 " outlet with 1/2 " inlet) 8666 Testip
1122 Manual Butterfly Valves for Gas and Air 3065 North American Aspirator Air/Gas Mixers
3070 High Pressure Inspirators 7128 Air/Gas Ratio Regulators
WARNING: Situations dangerous to personnel and property may exist with the operation and maintenance of any combustion equipment. The presence of fuels, oxidants, hot and cold combustion products, hot surfaces, electrical power in control and ignition circuits, etc., are inherent with any combustion application. Components in combustion systems may exceed 160°F (71°C) surface temperatures and present hot surface contact hazard. Fives North American Combustion, Inc. suggests the use of combustion systems that are in compliance with all Safety Codes, Standards, Regulations and Directives; and care in operation.
CONTACT fna.sales@fivesgroup.com T +1 800 626 3477 - F +1 216 373 4237
Fives North American Combustion, Inc. 4455 East 71st Street - Cleveland, OH 44105 - USA www.fivesgroup.com