Combustion Catalog | Fives North American

Capacity | Premix Gas Burner Nozzles

COMBUSTION AIR CAPACITIES TABLE 1

For approximate kW LHV with ambient air temperature multiply Nm 3 /h capacity by 1

For approximate Btu/h HHV with ambient air temperature multiply scfh air capacity by 100

Burner

Flow in SCFH with Mixture Pressure Inches w.c.

Flow in Nm 3 /h with Mixture Pressure mbar

Designation 1 4682-0-A 200 4682-0-B 250 4682-0-C 280 4682-1-A 350 4682-1-B 440 4682-2-A 560 4682-2-B 650

2

5

6

7

10

12 2.5

5 12.5 15 17.5 10

30

280 350 400 490 620 790 920

440 560 640 790 990

480 610 700 860

520 660 750 920

- - - - - - - - - - -

- - - - - - - - - - -

5.35 7.48 11.8 12.8 13.9 6.68 9.36 15.0 16.3 17.6 7.48 10.7 17.1 18.7 20.0 9.4 13.1 21.1 23.0 24.6 11.8 16.6 26.5 28.6 31.0 15.0 21.1 33.7 36.6 39.6 17.4 24.6 39.0 42.5 46.0 20.8 29.4 46.8 51.1 55.1 23.5 33.1 52.9 57.5 62.0 26.2 36.9 58.8 63.9 69.2 32.1 45.2 71.9 78.3 84.7

- - - - - - - - - - -

- - - - - - - - - - -

1070 1370 1590 1910 2150 2390 2930 3660 4650 5000 6000 7100 7800

1160 1480 1720 2060 2320 2590 3170

1260 1460

4682-2-C 780 1100 1750 4682-2-D 880 1240 1980 4682-3-A 980 1380 2200 4682-3-B 1200 1690 2690 4682-4-A 1500 2120 3360 4682-4-B 1900 2680 4270 4682-4-C 2050 2890 4610 4682-5-A 2450 3450 5500 4682-5-B 2900 4100 6500 4682-6-A 3200 4510 7200 4682-6-B 3850 5450 8650

3960 4760 5150 40.1 56.7 89.8 97.8 106 127 138

5000 6000 6550 50.8 71.6 114 5400 6500 7050 54.8 77.2 123 6500 7750 8450 65.5 92.2 147 7650 9200 10000 77.5 110 174 8450 10100 11000 85.5 121 192

124 134 160 175 134 144 174 188 160 174 207 226 190 204 246 267 208 226 270 294 251 273 326 353 275 299 358 390 310 337 401 454 393 422 508 551 460 497 593 647 684 740 887 968

9400 10200 12200 13200 103 146 231

4682-6-C 4250 6000 9550 10300 11200 13400 14600 114 160 255 4682-7-A 4750 6700 10600 11600 12600 15000 17000 127 179 283 4682-7-B 6000 8450 13400 14700 15800 19000 20600 160 226 358 4682-7-C 7050 9950 15800 17200 18600 22200 24200 188 266 422 4682-8-A 10500 14800 23500 25600 27000 33200 36200 281 396 628 4682-8-B 13000 18400 29200 31800 34400 41300 44900 347 492 781

850 920 1104 1200 4682-8-C 18000 25500 40400 44000 47600 57000 62000 481 682 1080 1176 1272 1524 1657 4382-8-D 21500 30200 48100 52500 57000 68000 74000 575 807 1286 1403 1524 1818 1978 4682-9 37700 53000 84500 92000 99500 - - 1008 1417 2259 2459 2660 - -

Note: — 4682 burner nozzles are available in inlet sizes from 3/4" NPT to 8" NPT. Except for the largest -9 (8") burner, each nozzle thread size is available with multiple center orifice sizes which provide different capacities. See ordering instruction on the next page.

— If secondary air is available around nozzle, the burner can be run fuel rich and Btu/hr capabilities increased by factors in the table below.

% Combustion Air Through Burner

Multiply

Capacity by

90 80 70

1.1

— Poor premix quality or insufficient straight piping runs into the burner nozzle can cause flame stability or flashback problems.

1.22 1.38

Bulletin 4682 Page 4

Made with FlippingBook flipbook maker