Combustion Catalog | Fives North American

Capacities | 4830 Evenglow ™ IT

4830 STANDARD CAPACITIES TABLE 1

Parameters

4830-600 4830-700 4860-800

kW

150

175

200

Maximum Firing Rate

Btu/h HHV

567,000

662,000

756,000

°C °F

850

850

850

Chamber Temperature

1,562

1,562

1,562

mm

152

178

203

Radiant Tube Minimum Dia

in.

6

7

8

Kcal/Nm 3 LHV

8,675 1,024

8,675 1,024

8,675 1,024

Calori fi c Value

Natural Gas Fuel for Data

Btu/ft 3 HHV

Stoichiometric Ratio

Air/Fuel

9.69

9.69

9.69

Nm 3 /hr Scf/hr

14.9 554

17.4 646

19.8 738

Fuel Flow Rate

mbar

12

12

12

Fuel Pressure

in w.c. Nm 3 /hr Scf/hr mbar

5

5

5

159

185

211

Combustion Air Flow Rate @ 10% XSA

5,903

6,887

7,870

Combustion Air Pressure with Neutral Tube (at radiant tube = 950 °C

87

87

87

in. w.c.

35

35

35

Nm 3 /hr Scf/hr

173

202

231

Exhaust Flow Rate @ 10% XSA Operation Exhaust Pressure to Achieve Neutral Tube

6,475

7,555

8,634

mbar

-12 -5.0 100

-12 -5.0 100

-12 -5.0 100

in. w.c.

mg/Nm 3 @ 3% O 2 ppm v d @ 3% O 2 mg/Nm 3 @ 3% O 2 ppm v d @ 3% O 2

Maximum NOx Emissions Maximum CO Emissions E ffi ciency as Available Heat

46 50 38

46 50 38

46 50 38

Typical* Performance with Radiant Tube = 950 °C

% LHV % HHV

>75 >68

>75 >68

>75 >68

* Actual performance dependent on tube size and configuration and must be determined per project.

Bulletin 4830 Page 3

Made with FlippingBook flipbook maker