UZ CLIP Noggin Support
Load Data
Fixings (3.4 x 35mm)
Noggin Type
Characteristic Capacity (kN)
Header
Incoming
Solid Timber
2
3
2.28
I–Joist
2
2
2.73
Installation Instructions Stage 1
I–Joist Noggin Fix UZ Clip to underside of I–Joist top flange with 2No 3.4 x 35mm square twist nails.
Solid Timber Noggin >50mm Wide Fix UZ Clip to underside of noggin with 2No 3.4 x 35mm square twist nails. An additional 1No 3.4 x 35mm square twist nail is required in the timber end. UZ Clips should be staggered.
Solid Timber Noggin <50mm Wide Fix UZ Clip to underside of noggin with 2No 3.4 x 35mm square twist nails. An additional 1No 3.4 x 35mm square twist nail is required in the timber end.
Stage 2
I–Joist Noggin Nail the UZ Clip to the top of the header joist with 2No 3.4 x 35mm square twist nails.
Solid Timber Noggin >50mm Wide Nail the UZ Clip to the top of the header joist with 2No 3.4 x 35mm square twist nails. A skew nail fixing will be required on the opposite side (approx. 75mm long).
Solid Timber Noggin <50mm Wide Nail the UZ Clip to the top of the header joist with 2No 3.4 x 35mm square twist nails.
The latest most up to date version will always be online and not in print or in downloaded pdf.
88
Technical support 01592 771132 / technical@itwcp.com / https://www.itwcp-offsite.co.uk
Made with FlippingBook Annual report maker