/
UZ CLIP Noggin Support
Load Data
Fixings (3.4 x 35mm)
Noggin Type
Characteristic Capacity (kN)
Header
Incoming
Solid Timber
2
3
2.28
I–Joist
2
2
2.73
Installation Instructions Stage 1
I–Joist Noggin Fix UZ Clip to underside of I–Joist top flange with 2No 3.4 x 35mm square twist nails.
Solid Timber Noggin <50mm Wide Fix UZ Clip to underside of noggin with 2No 3.4 x 35mm square twist nails. An additional 1No 3.4 x 35mm square twist nail is required in the timber end.
Solid Timber Noggin >50mm Wide Fix UZ Clip to underside of noggin with 2No 3.4 x 35mm square twist nails. An additional 1No 3.4 x 35mm square twist nail is required in the timber end. UZ Clips should be staggered.
Stage 2
I–Joist Noggin Nail the UZ Clip to the top of the header joist with 2No 3.4 x 35mm square twist nails.
Solid Timber Noggin <50mm Wide Nail the UZ Clip to the top of the header joist with 2No 3.4 x 35mm square twist nails.
Solid Timber Noggin >50mm Wide Nail the UZ Clip to the top of the header joist with 2No 3.4 x 35mm square twist nails. A skew nail fixing will be required on the opposite side (approx. 75mm long).
The latest most up to date version will always be online and not in print or in downloaded pdf.
88
Technical support 01592 771132 / technical@itwcp.com / https://www.itwcp-offsite.co.uk
Made with FlippingBook Annual report maker