Fluke Australia 2021 Test Tools Catalogue

Fluke 77IV Digital Multimeter

Versatile multimeter for field service or bench repair The Fluke 77IV Digital Multimeter has the features needed to repair most electrical and electronic problems This meter is simple to use and has significant improvements over Fluke’s original 70 Series with more measurement functions, conformance to the latest safety standards, and a much larger display that is easier to view • Wide 1000 V measurement range • Average responding AC measurements • 0 3% accuracy • 10 amps continuous

Recommended Accessories

i400 AC Current Clamp See page 149

C35 Soft Carrying Case See page 153

• Frequency and capacitance • Resistance and continuity • Large display • Backlight for work in dim areas

TPAK Magnetic Meter Hanger See page 155

TL225 SureGrip™ Stray Voltage Adapter Test Lead Kit See page 145

• Min/Max to record signal fluctuations • Integral holster with probe holders • Free your hands with the optional TPAK magnetic hanger • Auto and manual ranging • Battery Life: 400 hours typical • Weight: 0 42 kg • Size (H×W×D): 185 mm × 90 mm × 43 mm • Limited lifetime manufacturer's warranty

Fluke 77IV

i2000 FLEX AC Current Clamp See page 149

TLK-225 SureGrip™ Master Accessory Kit See page 145

Function Voltage DC Voltage AC Current DC Current AC Resistance Capacitance Frequency

Maximum

Max resolution

Accuracy ±(0 3%+1) ±(2 0%+2) ±(1 5%+2) ±(2 5%+2) ±(0 5%+1) ±(1 2%+2) ±(0 1%+1)

1000 V 1000 V

1 mV 1 mV

10 A 10 A

0 01 mA 0 01 mA

50 MΩ

0 1 Ω 1 nF

9,999 μF 99 99 kHz

0 01 Hz

Accuracies are best accuracies for each function

General Specifications Accuracy is specified for 1 year after calibration, at operating temperatures of 18°C to 28°C, with relative humidity at 0% to 90% Accuracy specifications take the form of ±([% of Reading] + [Counts])

Specifications

77IV

V Maximum voltage between any terminal and earth ground

1000 V

Surge protection

8 kV peak per IEC 61010 440 mA, 1000 V FAST Fuse 11 A, 1000 V FAST Fuse

W Fuse for mA input W Fuse for A input

Display

Digital: 6,000 counts, updates 4/sec

Bar Graph Frequency Capacitance

33 segments, updates 32/sec

10,000 counts 1,000 counts 2,000 metres 12,000 metres -10°C to + 50°C -40°C to + 60°C

Operating altitude Storage altitude

Operating temperature Storage temperature Temperature coefficient

Included Accessories Test Leads with 4 mm Lantern Tips, 9V Battery (installed), Manual Information Pack Ordering Information FLUKE-77-4 Digital Multimeter

0 1 × (specified accuracy/°C (< 18°C or > 28°C)

Electromagnetic compatibility (EN 61326-1:1997) Relative humidity (maximum non-condensing)

In an RF field of 3 V/M, accuracy = specified accuracy except in temperature: specified accuracy ± 5°C

90% to 35°C; 75% to 40°C; 45% to 50°C

Battery life

400 hours

Size (H×W×L) and Weight

185mm × 90mm × 43mm; 420 grams

Safety compliance

ANSI/ISA S82 02 01, CSA C22 2-1010 1, IE 61010 to 1000 V Measurement Category III, 600 V Measurement Category IV

C ontact your local distributor for price and availability. fluke.co/wtb

Certifications

CSA, TÜV (EN61010), UL, ∏, (N10140), VDE

fluke.co/dmm

Digital Multimeters

23

Made with FlippingBook Learn more on our blog