BC2S 7B
NEW
Floor-standing indirect cylinder with double coil
/ Tank protection with exclusive titanium-based enamel treatment at 850˚C / Double coil suitable to couple solar and fossil sources / Equipped for recirculation / 105 mm front inspection flange / Magnesium anode / Adjustable support feet / 2 kW electrical integration kit or 6 kW (450 L) available on request / Two sensor pockets
/ Thermometer included / PVC soft jacket included
FRONT
REAR
TECHNICAL DATA
BC2S 200 BC2S 300 BC2S 450
A
UPPER COIL Coil capacity Coil surface
l
3,2 0,5
6
7,5
m2 kW kW
0,8
1
Exchanger output (En 15332) Exchanger output (En 12897)
10
14,5 13,8
20
9,8
17,4
Coil resistance
mbar
9
11
10
BOTTOM COIL Coil capacity
l
5
9,6
13
Coil surface
m2 kW kW
0,8
1,3
2
Exchanger output (En 15332) Exchanger output (En 12897)
14
22,4
38 25
12,5
17,9
Coil resistance
mbar
12
16
17
Max. working pressure Thermal loss EN 60379 Maximum temperature
bar
7
7
7
kWh/24h
1,46
1,66
1,92
°C kg
90 80
90 107
90
Weight
150
DIMENSIONS A - Diameter
mm mm mm mm mm mm mm mm mm mm mm mm
656 1331 374 255 374 474 605 705 805 905 1005
656 1853 374 255 374 474 885 985 1135 1295 1455
751
B - Height / Water outlet Ø1" G Male C - Lateral flange Ø105mm D - Coil outlet Ø1" G Female E - Water inlet Ø1" G Male F - Sensor pocket Ø10mm G - Coil inlet Ø1" G Female H - Recirculation Ø3/4" G Female
1978 374 255
374 474
Water outlet Ø1" G Male
1045 1145 1295 1435 1575 825
I - Coil outlet Ø1" G Female J - Sensor pocket Ø10mm K - Coil inlet Ø1" G Female
Thermometer
Coil inlet Ø1" G Female Recirculation Ø3/4" G Female Sensor pocket Ø10 Water inlet Ø1" G Male Coil outlet Ø1" G Female Sensor pocket Ø10 Coil outlet Ø1" G Female Coil inlet Ø1" G Female
L - Width including flange plastic cover
730
730
BC2S 7B
200
300
450
Lateral flange Ø105mm
Energy class
B
B
B
CODE
3070616
3070617
3070618
| 69
Made with FlippingBook Annual report