Ariston Solar Water Heaters

Authorized distributor of top-quality MEP related products with 7 branches across the UAE.

Solar Water Heating Systems and Cylinders

WATER HEATERS

SOLAR SYSTEMS

HEAT PUMPS

GAS BOILERS

The home of sustainable comfort

As a leading specialist in heating and water-heating with over 90 years of history, Ariston understands well the challenges in creating practical and high-performance products and systems

why it has set itself a new mission – to give more homes access to sustainable comfort solutions

To this end, it has further strengthened its commitment to delivering that can simplify and improve the quality of home life while empowering people to live more sustainably.

By successfully combining its global reach with an in-depth focus

Ariston prides itself in being the home of sustainable comfort: a reference brand trusted worldwide by millions of families and industry professionals longing for advanced thermal comfort solutions that not only are easy to use and maintain but also use as little energy as possible .

| 3

Our story, driven by your needs

Ariston’s continuous growth has been fueled by its commitment to provide people with reliable and highly-ecient comfort solutions to improve and enjoy life at home. Each step of the way we have been driven by the existing and emerging needs of our customers, and our solutions have been conceived with their lifestyle in mind.

'30s

Foundation Aristide Merloni founds “Industrie Merloni” company in the Marche Region of Italy, and starts the production of weighing scales.

'80s

Heating We consolidate our market

leadership in water heating and the production of boilers begins.

'60s Water heating The Ariston brand is launched and the production of electric water heaters begins.

| 4

'90s

Global expansion With the launch in China and Russia, we begin to evolve into a global brand.

'10s

Ariston Comfort Challenge With this mission, Ariston proved the ability of its products to guarantee exceptional in every condition, even where it seems impossible. It was a huge challenge, but it was just the beginning.

'00s

'20s

The home of sustainable comfort We strengthen our commitment to providing our end-users with products that generate and renewable way possible. A tangible sign of our dedication to respecting everything that surrounds us.

Renewable technologies We successfully develop and launch our new model in heat pump, which marks our development into innovative and sustainable heating technology.

| 5

Believe in sustainability

development goals endorsed by the General Assembly of the United Nations.

Our purpose is to provide everyone, in every corner of the world, with high-quality heating and water heating solutions, while protecting the environment . To this end, we have placed energy from renewable sources at the centre of our sustainable growth strategy, thus acting consistently with the sustainable

products, solutions and processes that can make a decisive contribution to reducing energy consumption and environmental impact without sacrificing comfort.

| 6

The economic, social and environmental impacts generated through Ariston Thermo Group’s operations contribute towards 9 of the 17 sustainable development goals, including: Sustainable cities and communities

technologies will allow to curb carbon dioxide emissions by more than 3,4 Mln tons by 2022*.

Responsible consumption and production All of our production plants around the world are at the centre of Ariston Thermo Group’s energy

the production processes.

Climate action During 2019 the Ariston Comfort Zone, a modular house equipped with Ariston’s most advanced

studies.

| 7

| 8

Our Services Pre-Sales and After-Sales technical support

We are always at your side In all phases of the realization of a project.

From the design of a plant, to the construction of the system itself and even after commissioning, a team of Ariston specialists is constantly available to provide support and assistance.

Pre-Sales A team of technicians and engineers oer their support and their experience in the design of key-on-hand solutions, providing them with products, designs and maintenance services.

Technical Consultancy Center The Technical Consultancy Center provides every day specialist consultancy and timely responses on the technical characteristics of installations. The technical team is the right interlocutor with whom interface for design and maintenance of complex plants. After-Sales Our qualified Service Network provides technical support for startup, maintenance, troubleshooting and repair interventions, by remote and on field as well. Our mission is to deliver high level of service, through solid know-how and quality of genuine spare parts, in order to ensure the Ariston products performance, long term reliability and make them exceed the Customer expectations.

| 9

SOLAR HEATING SYSTEMS

KAIROS THERMO CF-3

KAIROS THERMO GR-2

| 10

KAIROS FAST CD1 CF-1 CD2 CF-1

KAIROS THERMO HF-2

ARISTON CARES!

delivery. The growing concern for the future of the environment we are living in, and the desire to leave a green and

and renewable products. Modern technologies like solar systems and air to water heat pumps perfectly serve the scope. They use a clean and renewable source, either sun or air, to heat the water thus giving you maximum comfort while reducing polluting emissions and protecting the environment.

Ariston Thermo Group, a leading brand in thermal comfort, has been proposing alternative

With its wide range of solar systems (both natural and forced circulation) and air-to-water

the right solution to give its end-user hot water with an environmentally friendly attitude.

Ariston Thermo Group has committed itself to a long-term challenge: reach 80% of its sold products

in the world we are living in.

DO YOU WANT TO TAKE PART TO THIS CHANGE?

ARISTON QUALITY: SIMPLY “MADE IN ITALY”

INTERNATIONAL QUALITY CERTIFICATION All Ariston factories are certified by CSQ, a member of the International Certification Network IQNet. As a result, all Ariston products are manufactured in compliance with the highest standards, guaranteeing reliability and high-quality. Every year all the plants are involved in a competition aimed to improve the quality level of the production. 3 MILESTONES OF QUALITY Customer satisfaction is Ariston’s main concern and this is why quality is constantly monitored at every level through: • Incoming control of the raw materials and components • Process Control aiming to intercept the potential defects in earlier stages of the manufacturing process • Product Testing of 100% of the production in the line to assure the correct functioning of the product

ITALIAN TECHNOLOGY & DESIGN Driven by innovation but still linked to its roots.

This is the perfect mix that represent Ariston attitude and that pushes the members of the R&D department to develop more ecient, eco-friendly and reliable products always with the quality and design typical of the Italian manufacturing tradition.

| 13

ARISTON SOLAR SYSTEMS: 30 YEARS OF EXPERIENCE AT YOUR SERVICE

WHEN YOU INSTALL AN ARISTON SOLAR SYSTEM AT YOUR HOME, YOU ARE NOT SIMPLY INSTALLING A PRODUCT; YOU ARE BRINGING AT YOUR HOME 30 YEARS OF EXPERIENCE, SYSTEM DESIGN, PRODUCTS TEST AND EVOLUTION. 1982 Ariston opens the first plant for the production of solar collectors to contrast rising price of oil in Europe, that at that time was incentivizing green technologies. In the first year the record production of 44.000 m2 was reached. Ariston Thermo immediately became a leader in this sector. The production was meant just for Italy at that time and we kept manufacturing collectors in Cerreto (Italy) till 2001.

1983

Ariston solar collectors are used to realize one full wall of a skyscraper in Milan.

2002 Acquisition of Elco company, leader in north west Europe in heating and with a long tradition in solar systems. All the products in the actual range are tested separately by Ariston (Italy) and Elco (Germany) to ensure covering all possible working conditions. 2004 Opening of a new solar plant in India for Indian Market only. Starting the production of vacuum tube in China. Tubes and manifold technology are patented by Ariston. 2007 Serra De’ Conti plant (Italy) was opened and became the center of the R&D dept for all the plants. Serra De’ Conti is one of the most technologically advanced plant in Europe.

2012 “Sun&wind Energy” magazine, places Ariston as first manufacturer of solar collectors in Italy

| 14

OBJECT: test on flat collectors according to 80/PDB/001 specification. Collector model RAV 1,8 4L/E3 With the following letter we are pleased to inform you that your collector model RAV 1.8 4L/E3, whose characteristics are those certified in the technical drawing sent to PHOEBUS and shown in the attached, are compliant to the 80/PDB/001 requirements and therefore, as soon as ENEL will promote solar water heaters to its end-users,

conditions agreed.

OUR FIRST SOLAR COLLECTOR WAS CERTIFIED IN 1983 BY THE ITALIAN NATIONAL BODY OF ENERGY.

| 15

ARISTON SOLAR THERMAL: QUALITY GUARANTEED

CERTIFIED ENERGY EFFICIENCY

EN 12975 Standard. All of this has been checked by strict tests performed at ac- credited research centres. The new products have acquired the Solar Keymark.

Ariston also distinguishes itself for the attention reserved for its customers in the after-sales period. The five year warranty covers the collector and the cylinder, while the electronic control unit, the pump unit and the accessory kits are guaranteed for two years.

LONGER LASTING AND SAFER The special highly transparent toughened glass of the Ariston collectors reflects the incident solar rays to a minimum, thus loosing little energy. The solar energy absorbed is also withheld thanks to its prismatic surface, which

ANTI-REFLECTIVE AND HAIL-PROOF

accompanied by the safety of toughened glass, tested against hail.

| 16

TYPE OF SOLAR SYSTEM

As for heat systems, the heat is transferred by means of a “heat carrying fluid” that runs between the solar panel and the cylinder. The fluid can run spontaneously or using a pump. On the basis of which the two types of solar systems are distinguished: natural or forced circulation.

THE SOLUTION TO ALL NEEDS

NATURAL CIRCULATION SIMPLE RELIABLE ECONOMIC REDUCED MAINTENANCE

FORCED CIRCULATION

EFFICIENT FLEXIBLE ARCHITECTONIC INTEGRATION IN SYMBIOSIS WITH THE BOILER

| 17

COMPLETE SYSTEMS

KAIROS THERMO CF-3

KAIROS THERMO GR-2

200-1

300-2

150-1

200-1

200-2 300-2

TYPE OF CIRCULATION

natural

natural

ROOF INSTALLATION

yes

yes

GROUND AND FLAT ROOF INSTALLATION

yes

yes

TYPE OF SYSTEM

indirect

indirect

ELECTRO SOLAR VERSION AVAILABLE

yes

yes

NUMBER OF COLLECTORS

1

1

2

2

1

2

GROSS AREA (m 2 )

2,01

1,96

EXPANSION VASE

not necessary

not necessary

SENSYS

not necessary

not necessary

TANK ENERGY CLASS

-

-

TANK EMPTY WEIGHT (kg)

60

100

50

60

60

85

30

COLLECTOR WEIGHT (kg)

27

yes

SOLAR KEYMARK

yes

20

PAGE

21

| 18

KAIROS THERMO HF-2

KAIROS FAST CD1 CF-1

KAIROS FAST CD2 CF-1

150-1

200-1

200-2

300-2

150-1

200-2

300-2

200-2

300-2

natural

forced

forced

yes

yes

yes

yes

yes

yes

indirect

indirect

indirect

yes

-

-

1

1

2

2

1

2

2

2

2

2,2

2,01

2,01

not necessary

included, 16 l

included, 16 l

not necessary

included

included

-

B

C

C

C

C

30

30

60

60

82

110

119

114

131

35

29,5

29,5

yes

yes (only collectors)

yes (only collectors)

22

26

26

| 19

Kairos Thermo CF-3

| 20

Kairos Thermo GR-2

| 21

Natural circulation solar system for production of domestic hot water

New heat exchanger with 3x performance for faster water heating* Increased rain penetration resistance for no-worry in any climate. Blue selective surface treatment grant 95% absorbtion and only 5% reflection. Fast, easy and risk-free installation with ‘insert and click’ connections.

Refined design Solar keymark certification Tempered glass with low iron Safety valve and thermostat* Features

| 22

| 23

| 24

MAIN SYSTEM LAYOUTS

L

N

LAYOUT A

LAYOUT B

S

SE

BUS

LAYOUT C

Sacs

| 25

Kairos Fast

Forced circulation solar system with integrated single/double coil tank for the production of domestic hot water

PERFORMANCES / The selective aluminium absorber forgives very high eciency, and reduced reflection; / The ultrasonic welding technology, on the collector, ensures very good performances for home applications; DESIGN AND TECHNOLOGY / The Sensys, the system interface included in the product, allows an easy navigation and a full control of all the working parameters, displaying the solar fraction, the storage of how water and the energy saving; / The preassembled storage oers the best enjoyble design of its category, thanks to the accurate study of the lines, and of the external shape; QUALITY / The collector’s solar key mark certifies the compliance with the international standard; / The protech anode guarantees anti-corrosion protection of the internal tank;

KAIROS FAST CD1 150-1

KAIROS FAST CD1 200-2

KAIROS FAST CD1 300-2

KAIROS FAST CD2 200-2

KAIROS FAST CD2 300-2

TECHNICAL DATA

SOLAR COLLECTORS

1-KAIROS CF 2.0-1

2-KAIROS CF 2.0-1

2-KAIROS CF 2.0-1 2 - KAIROS CF 2.0 -1 2 - KAIROS CF 2.0 -1

2

Collectors gross surface

m

2,01

4,02

4,02

4.02

4.02

2

Collectors aperture surface

m

1,74

3,48

3,48

3.48

3.48

STORAGE TANK MODULE

Dimensions (L x H x P)

mm

697 x 965 x 889 697 x 1260 x 889 697 x 1782 x 889 697 x 1260 x 889 697 x 1782 x 889

Domestic hot water storage tank capacity Heat loss

l

142

198

298

192

292

kWh/24h

1,1

1,49

2,28

1.49

2.28 7

DHW circuit minimum pressure

bar

7

7

7

7

DHW circuit max. pressure

mca

4,5

4,5

4,5

4,5

4,5

Solar expansion vessel capacity

l

16

16

16

16

16

Solar circuit safety valve calibration

bar

6

6

6

6

6

KAIROS FAST

CD1 150-1

CD1 200-2

CD1 300-2

CD2 200-2

CD2 300-2

Energy class

B

C

C

C

C

TR

3023637

3023639

3023645

3023641

3023645

TT

3023638

3023640

3023646

3023642

3023646

ACCESSORIES

CODE

SOLAR/DHW ADDITIONAL EXPANSION VESSEL ( 16L ) FOR MACC

3024183

| 26

LIST OF COMPONENTS KAIROS FAST

Description

KAIROS FAST CD1 150-1 TR

1

1

1

2

1

1

1

KAIROS FAST CD1 150-1 TT

1

1

1

1

1

1

KAIROS FAST CD1 200-2 TR

1

2

2

2

1

1

1

1

KAIROS FAST CD1 200-2 TT

1

2

1

1

1

1

1

KAIROS FAST CD2 200-2 TR

1

2

2

2

1

1

1

1

KAIROS FAST CD2 200-2 TT

1

2

1

1

1

1

1

KAIROS FAST CD1 300-2 TR

1

2

2

2

1

1

1

1

KAIROS FAST CD1 300-2 TT

1

2

1

1

1

1

1

KAIROS FAST CD2 300-2 TR

1

2

2

2

1

1

1

1

KAIROS FAST CD2 300-2 TT

1

2

1

1

1

1

1

* DOCUMENTATION MACC (IT-EN) Code 3105018; DOCUMENTATION MACC (HU-PL-RO-CZ-RU-UA) Code 3105021; DOCUMENTATION MACC (TK-RU-GR-HR-SRB-UA) Code 3105022

| 27

Kairos Fast

CD1

889

645

996 1004

628

383

78

233

OVERALL DIMENSIONS

CD1 150-1 CD1 200-2 CD1 300-2 1782 1260 965

251

A

mm

645

CD2

889

645

996 1004

78

628

383

OVERALL DIMENSIONS

CD2 200-2 CD2 300-2 1782 1260

A B C

mm mm mm

649 808

1170 1330

233

251

645

| 28

MAIN LAYOUTS

A

B

| 29

Kairos Macc

Single/double coil pre-assembled tank module for the production of domestic hot water

/ The storage’s polyurethane insulation free of CFC & HCFC allows maximum protection against heat losses; / The storage can disperse up to 1,5 kWh/24 h (150 lt): one of the lowest value of its category; / The arrangement for an additional expansion vessel makes the product suitable for big solar systems; / The accurate design of the heat exchange surface can provide a big amount of hot water; / The motorized mixing valve gives you the possibility to set the desired temperature; / The preassembled storage oers the best enjoyble design of its category, thanks to the accurate study of the lines, and of the external shape; / The air purge valve protects from air accumulation; / The preassembled hydraulic safety group protects the storage from high pressure working conditions;

TECHNICAL DATA

CD1 150

CD1 200

CD1 300

CD2 200

CD2 300

Domestic hot water storage tank capacity

l

142

198

298

192

292

DHW circuit max. pressure

bar

7

7

7

7

7

2

0.85

0.85

0.85

0.85

0.85

Lower coil surface

m

2

0.8

0.8 85 4.5 16

Upper coil surface

m

Max operating temperature

°C

85

85

85

85

O

4.5

4.5

4.5

4.5

Max solar pump head

m. H

2

Solar expansion vessel capacity

l

16

16

16

16

Solar circuit capacity

l

6

6

6

6

6

Upper exchanger capacity

l

4.5

4.5 6

Solar circuit safety valve calibration

bar

6

6

6

6

Tank's thermal dispersions

kWh/24h

1.1

1.49

2.28

1.49

2.28

Empty mass

kg

82

106

119

110

131

KAIROS MACC

CD1 150

CD1 200

CD1 300

CD2 200

CD2 300

Energy class

B

C

C

C

C

(IT-EN)

3023271

3023272

3023273

3023274

3023275

(HU-PL-RO-CZ)

3023303

3023304

3023305

3023306

3023307

(TK-RU-GR-HR-SRB-UA)

3023308

3023309

3023310

3023311

3023312

ACCESSORIES

CODE

SOLAR/DHW ADDITIONAL EXPANSION VESSEL ( 16L ) FOR MACC

3024183

| 30

1 Sensys user interface 2 Solar safety valve 3 Pressure sensor 4 Motorised thermostat - controlled mixing valve 5 Hydraulic safety assembly with siphon 6 Connection for additional solar vessel / domestic water expansion vessel 7 Solar fluid collection tank with indicator

1

8 Flow meter 9 Solar pump 10 16 litre solar expansion vessel 11 Pressure gauge 12 Deareator

12

2

10

11

3

9

4

8

5

6

7

LIST OF COMPONENTS KAIROS MACC

Description

Code

KAIROS MACC CD1 150 (IT-EN)

3023271

1

1

KAIROS MACC CD1 150 (PL-CZ-HU-RO)

3023303

1

1

KAIROS MACC CD1 150 (TK-HR-SRB-GR-RU-UA)

3023308

1

1

KAIROS MACC CD1 200 (IT-EN)

3023272

1

1

KAIROS MACC CD1 200 (PL-CZ-HU-RO)

3023304

1

1

KAIROS MACC CD1 200 (TK-HR-SRB-GR-RU-UA)

3023309

1

1

KAIROS MACC CD1 300 (IT-EN)

3023273

1

1

KAIROS MACC CD1 300 (PL-CZ-HU-RO)

3023305

1

1

KAIROS MACC CD1 300 (TK-HR-SRB-GR-RU-UA)

3023310

1

1

KAIROS MACC CD2 200 (IT-EN)

3023274

1

1

KAIROS MACC CD2 200 (PL-CZ-HU-RO)

3023306

1

1

KAIROS MACC CD2 200 (TK-HR-SRB-GR-RU-UA)

3023311

1

1

KAIROS MACC CD2 300 (IT-EN)

3023275

1

1

KAIROS MACC CD2 300 (PL-CZ-HU-RO)

3023307

1

1

KAIROS MACC CD2 300 (TK-HR-SRB-GR-RU-UA)

3023312

1

1

* MACC Documentation (IT-EN) Code 3105018; MACC Documentation (HU-PL-RO-CZ-RU-UA) Code 3105021; MACC Documentation (TK-RU-GR-HR-SRB-UA) Code 3105022; | 31

Kairos Macc

CD1

889

645

628

383

233

OVERALL DIMENSIONS

8 CD1 150 CD1 200 CD1 300 1782 1260 965

251

A

mm

645

CD2

889

645

628

383

OVERALL DIMENSIONS

110 CD2 200 131 CD2 300 1782 1260

A

mm

B

mm

649

1170

C

mm

808

1330

233

251

645

| 32

MAIN LAYOUTS

A

B

| 33

Kairos Combi

Integrated tank for the solar heating integration and for the production of domestic hot water

/ The soft 100 mm insualation allows maximum protection against heat losses; / The high residual head (6,5 m) of the pump gruop assures the proper working of big systems; / Kairos Combi includes all the accessories needed for a complete installation: the digit pump group, the digital manometer, the digital flow meter... / The Sensys, the system interface included in the product, allows an easy navigation and a full control of all the working parameters, displaying the solar fraction, the storage of how water and the energy saving; / The air purge valve protects from air accumulation inside the system; / The preassembled hydraulic safety group protects the storage from high pressure working conditions;

TECHNICAL DATA

CK1 400

CK1 600

CK1 800

CK1 1000

Domestc hot water storage tank capacity

l

400

600

800 2.8 17.5

1000

Coil surface

1.5

2.1 13

3.4

Solar coil capacity

l

9.3

21

Max operating tank pressure Max operating temperature

bar

3

3

3

3

°C kg

95 92

95 113

95

95 176

Empty mass

155

DHW PRODUCTION MODULE (WITH DHW RECIRCULATION ACCESSORY)

FRESH WATER STATION

Temperature range Minimum flow rate

°C

36 ÷ 65

l/min l/min

2.5

Sanitary flow rate measurer Max primary circuit pressure Max DHW circuit pressure

2.5 ÷ 32

bar bar

3 6

Max DHW/primary circuit temperature

°C

85

Electrical supply/Frequency

V/Hz

230 / 50 40 (100)

Power consumption

W

Hydraulic DHW/primary circuit connections

¾” M

Dimensions (H x L x P)

mm

700 x 400 x 295

Mass

Kg

16 (18)

Max DHW flow rate (70°C , ∆T=30°)

l/min

32

PUMP GROUP

DIGIT SOLAR PUMP GROUP

Solar circuit flow rate range Max solar circuit pressure

l/min

1 ÷ 16

bar

6

Max heat transfer fluid temperature

°C

130

Electrical supply/Frequency

V/Hz

230 / 50

Power consumption

W

97

NTC (10kΩ β =3977)

Flow and return temperature sensor

Hydraulic conections

¾” M or smooth tube ø 18 mm

Weight

kg

6.5

Dimensions (LxHxP)

mm

275 x 480 x 200

KAIROS COMBI

CK1 400

CK1 600

CK1 800

CK1 1000

Energy class

B

C

C

C

CODE

3023285

3023286

3023287

3023288

ACCESSORIES

CODE

DHW module recirculation kit

3024161

Electrical kit 1.5 kW 230 V 1”, 1/2

935393

Electrical kit 2.5 kW 230-400 V 1”, 1/2

935394

Electrical kit 6 kW 400 V 1”, 1/2

3078066

Safety group

12053830

| 34

*

400

600 1645 1550 1400 1294 1000 900

800 1495 1405 1315 1309 1060 950 855 775 500 260 1805 1190 990 790 690

1000 1730 1640 1550 1434 1185 1075

A 1240 B 1150 C 1060 D 1164 E 880

3 2 1

125 275

85

200

F

785

G 700 H 630

815 760 405 230

980 900 500 260

6 5 4

I

415 235

L

M 1630 N 1000 O 800 P 600 Q 695

1945 1050 850 650

2055

1190 990 790 690

8 7

720

1

1” F

1” F

1” F

1” F

N

2 ½” F

½” F

½” F

½” F

O

3

1” F

1” F

1” F

1” F

4 1” ½ F 5 ½” F 6 1” F

1” ½ F

1” ½ F

1” ½ F

P

½” F

½” F

½” F

1” F

1” F

1” F

7

½” F

½” F

½” F

½” F

8 1” F 9 1” F

1” F 1” F

1” F 1” F

1” F 1” F

9

*dimenson in mm

LIST OF COMPONENTS KAIROS COMBI

Description

KAIROS COMBI CK1 400

1

1

1

1

1

1

1

1 1

KAIROS COMBI CK1 600

1

1

1

1

1

1

1

KAIROS COMBI CK1 800

1

1

1

1

1

1

1

1

KAIROS COMBI CK1 1000

1

1

1

1

1

1

1

1

** Sensys (IT-EN-FR-ES-PT) Code 3318585; Sensys (PL-CZ-HU-RO) Code 3318615; Sensys (TK-RU-GR-HR-SRB) Code 3318613.

Grafico portate acqua sanitaria disponibili (temperatura di rete 10°C) 40 45 50 55 60 65 70 75 80 85 0 5 10 15 20 25 30 35 40 45 50 set point 60°C set point 50°C set point 40°C Grafico portate acqua sanitaria disponibili (temperatura di rete 10 °C)

Grafico portata Gruppo pompa digitale (temperatura di rete 10 °C)

700

Velocità II

600

Velocità III

500

400

300

200

100

Portata (l/h) 0 100 200 300 400 500 600 700 800 900 1000 0

Portata sanitaria [l/min]

| 35

Kairos Combi

MAIN LAYOUTS

A

C

B

*

*

B A C

*

*diverter valve to be ordered separately cod. 3024177

| 36

COLLECTORS FOR FORCED CIRCULATION

KAIROS XP 2.5-1V KAIROS XP 2.5-1H KAIROS THERMO GR2 KAIROS CF2.0-1

2,53

2,53

2,02

2,01

GROSS AREA (m 2 )

2,01

2,53

2,53

2,04

APERTURE AREA (m 2 )

1,83

2,26

2,26

1,94

ABSORBER AREA (m 2 )

1,74

2,24

2,24

2,01

30

EMPTY WEIGHT (kg)

46

46

29

STAGNATION TEMPERATURE (°C)

198

193

190

179

HEIGHT (mm)

61

61

78

80

LENGTH (mm)

2241

1128

2004

1960

WIDTH (mm)

1128

2241

1004

1040

INCLINED ROOF INSTALLATION

Yes

Yes

Yes

Yes

GROUND/FLAT ROOF INSTALLATION

Yes

Yes

Yes

Yes

BUILT-IN INSTALLATION

Yes

Yes

Yes

Yes

MAX NUMBER OF COLLECTORS

10

10

6

10

SOLAR KEYMARK

Yes

Yes

Yes

Yes

PAGE

38

40

44

42

| 37

Kairos XP 2.5-1V

Solar collector for forced circulation

/ Kairos XP 2.5-1 has a serpentine absorber that makes it suitable for big systems; / The blue selective surface treatment provides very high performances with the 95% absorbtion and only 5% reflection; / Kairos XP 2.5-1 oers a very enjoyble design in its category, thanks to the accurate study of the lines, and of the external shape; / The new o-ring connection allows a very quick installation, even eliminating the risk to damage the hydraulic connection kit; / The special tempered glass with low content iron assures very high protection against the hail, and against the collector’s loading; / The technopolymer angle, that integrates the condensate exhaust and the flanged manifold outlet, ensures a more precise production process;

TECHNICAL DATA

KAIROS XP 2.5-1V

Empty mass

Kg

46

Working pressure

bar

6

Collector pipe diameter

mm

18

m 2

2.51

Gross surface

Amount of collector liquid

l

2.1

Absorption

%

95

Emission

%

5

m 2

2.26

Aperture surface

m 2

2.24

Absorbent surface

Specific thermic capacity

kJ/K

15.32

η 0

0.81*

W/m 2

K

3.13*

k

1

W/m 2 K 2

0.016*

k

2

T stagnation

°C

198

* data refers to the aperture area

Solar collector eciency curve

1,0 0,9 0,8 0,7 0,6 0,5 0,4 0,3 0,2 0,1 0,0

P peak =1.832 W

KAIROS XP

2.5-1V

CODE

3020058

0,00 0,01 0,02 0,03 0,04 0,05 0,06 0,07 0,08 0,09 0,10

(T

-T

)/G K/(W/m 2 )

collector liquid average

environment

G = 1000 W/m 2

| 38

Up to 10 collectors

Up to 5 collectors

1

2

3

4

5

6

7

8

9

10

Description

Code

TT TR IN TT TR IN IN² TT TR IN IN² TT TR IN IN² TT TR IN IN² TT TR IN IN² TT TR IN IN² TT TR IN IN² TT TR IN IN² TT TR IN IN²

KAIROS XP 2.5-1 V

3020058 1 1 1 2224 33364 4 4855510666127 7 714888169991810101020

Hydraulic connec- tion set 1 collector Hydraulic connection set 1 collector ext.

111111211121112111211121112111211121112

3024093

1 1 1 22224333644485551066612777148881699918

3024094

Horizontal Bars

3024104

1 1

2 2

3 3

4 4

5 5

6 6

7 7

8 8

9 9

10 10

Triangle

3024103

2

2

3

4

5

6

7

8

9

10

Inox Fixing Straps*

3024112

2

3

4

5

6

7

8

9

10

11

In-roof kit (1 collector) In-roof kit (2 collectors)

1

3721434

3721428

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

In-roof kit (additional collector) 2nd row in-roof kit (2 collectors) 2nd row in-roof kit (additional collector)

3721429

1 1

2 2

3 3

4 4

5 5

6 6

7 7

8 8

3721430

1

1

1

1

1

1

1

1

1

3721431

1

2

3

4

5

6

7

8

special fixing frame for sloped roof for xp collector

Description

Codice

Disegno

Bent tile fixing brackets (pair)

3024113

Flat tile fixing brackets (pair)

3024114

Slate tile fixing brackets (pair)

3024083

Undulating roof fixing screws (pair)

3024115

Wooden roof fixing screws (pair)

3024116

| 37

Kairos XP 2.5-1H

Solar collector for forced circulation

/ Kairos XP 2.5-1 has a serpentine absorber that makes it suitable for big systems; / The blue selective surface treatment provides very high performances with the 95% absorbtion and only 5% reflection; / Kairos XP 2.5-1 oers a very enjoyble design in its category, thanks to the accurate study of the lines, and of the external shape; / The new o-ring connection allows a very quick installation, even eliminating the risk to damage the hydraulic connection kit; / The special tempered glass with low content iron assures very high protection against the hail, and against the collector’s loading; / The technopolymer angle, that integrates the condensate exhaust and the flanged manifold outlet, ensures a more precise production process;

TECHNICAL DATA

KAIROS XP 2.5-1H

Empty mass

Kg

46

Working pressure

bar

6

Collector pipe diameter

mm

18

m 2

2.51

Gross surface

Amount of collector liquid

l

2.5

Absorption

%

95

Emission

%

5

m 2

2.26

Aperture surface

m 2

2.23

Absorbent surface

Specific thermic capacity

kJ/K

17.98

η 0

0.81*

W/m 2

K

3.02*

k

1

W/m 2 K 2

0.017*

k

2

T stagnation

°C

193

* data refers to the aperture area

Solar collector eciency curve

1,0 0,9 0,8 0,7 0,6 0,5 0,4 0,3 0,2 0,1 0,0

P peak =1.832 W

KAIROS XP

2.5-1H

CODE

3020057

0,00 0,01 0,02 0,03 0,04 0,05 0,06 0,07 0,08 0,09 0,10

(T

-T

)/G K/(W/m 2 )

collector liquid average

environment

G = 1000 W/m 2

| 40

Up to 10 collectors

Up to 5 collectors

1

2

3

4

5

6

7

8

9

10

Description

Code

TT TR TT TR TT TR TT TR TT TR TT TR TT TR TT TR TT TR TT TR

KAIROS XP 2.5-1 H

3020057

1

1 22334455667788991010

Connection set 1 coll

3024093

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

Connect set 1 additional coll XP

3024094

1

1 2233445566778899

Horizontal bars (XP 2.5-1 H)

3024106

1

1 22334455667788991010

Triangle (XP 2.5-1 H)

3024105

2

3

4

5

6

7

8

9

10

11

Inox fixing straps* (pair)

3024112

2

3

4

5

6

7

8

9

10

11

special fixing frame for sloped roof for xp collector

Description

Codice

Disegno

Bent tile fixing brackets (pair)

3024113

Flat tile fixing brackets (pair)

3024114

Slate tile fixing brackets (pair)

3024083

Undulating roof fixing screws (pair)

3024115

Wooden roof fixing screws (pair)

3024116

| 41

Kairos THERMO GR2

Solar collector for forced circulation

Clear tempered solar glass 3,2mm Transparent glass Transmittance 0,90

selective coating Laser welded Copper harp: 2 headers X Ø22x0,7 ;10 risers X Ø8x0,40

Solar absorption: 95% Thermal emissivity: 5%

Mineral Wool/30mm (back), 15mm (lateral) Density 24kg/m3

Aluminum 0,6mm

TECHNICAL DATA

THERMO GR2

mm

Extrenal dimensions (height × width × thickness)

1960 ×1040×80

m ²

2,04

D

Gross area

1,94

Aperture area

2,01

Absorber area

L

1,71

Absorber capacity

mm

Frame / thickness

Anodized Aluminum frame with a back plate of Aluminum / 0,4

Glass

Clear tempered glass 3,2mm; (transmittance 0,90)

Insulation

Mineral Woo; 30mm back, 15mm Lateral Aluminum

Absorber Absorbtion

C B

%

95

%

Emission

5

η 0

Header copper tube Ø / thickness Conversion factor Riserer copper tube Ø / thickness

0,72

mm

Ø 22 / 0,70

mm

Ø 8 / 0,40

No.

8

Number of vertical risers

Bar

Maximum operating pressure

10

A

Installation

Vertical

Kg

29

Weight (empty & packed)

 C

179  C

Stagnation temperature

KAIROS ENERGY EVO

A 1110 mm

B 1960 mm

C 1910 mm

KAIROS ENERGY EVO

D 1040 mm

CODE

3020077

| 42

HYDRAULIC CONNECTIONS

A: Connecting collectors in parallel with diagonal hydraulic connections

The collectors can be connected in parallel using the joint kit. A maximum of 6 collectors can be connected in parallel per row.

The inlet and outlet connections of the collector array must be arranged in such a way as to form a diagonal connection (with the inlet at the bottom of one side of the array and the outlet at the top of the other side).

B: Connecting collectors in series

A single collector array may be connected in series to another array. It is important that the number of collectors is the same in each row in order to avoid dierences in fl ow rate within the arrays.

C: Connecting collector arrays in parallel

A single collector array may be connected in parallel to another array. It is important that the number of collectors is the same in each row in order to avoid dierences in flow rate within the arrays. Hydraulic connection should be carried out according to the principle of reverse return.

2

3

1

| 43

Kairos CF 2.0-1

Solar collector for forced circulation

/ Absorber with highly selective treatment to titanium oxides (95% absorption 5% emission) / Hail-proof anti-reflective glass / Hydraulic circuit with copper pipes / Harp geometry and continuous ultrasound welding / Designed and sized for functioning in systems with forced circulation / Can be inclined between 30° and 60° / Test report according to en 12975

TECHNICAL DATA

KAIROS CF 2.0-1

Empty weight

kg

30

Working pressure

bar

6

Collector pipe diameter

mm

18

Amount of collector liquid

l

1.0

Absorption

%

95

Emission

%

5

Aperture surface

1.83

Absorbent surface

1.74

Specific heat capacity

kJ/K

13

0

0.74*

k1

W/m²K

3.82*

k2

W/m²K²

0.013*

stagnation T

°C

190

* data referring to the aperture area

KAIROS CF 2.0-1

2.0-1

Solar collector eciency chart

CODE

3020072

1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.0

P peak =1,357 W

0.00 0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.08 0.09 0.10

(T

-T

)/G K/(W/m 2 )

collector (average)

environment

G = 1000 W/m 2

| 44

FLAT SOLAR COLLECTOR

Up to 6

1883 2004

FLAT ROOF AND GROUND INSTALLATION

1

2

3

4

5

6

TT

TR

Description

Codice TT

TR TT

TR TT

TR TT

TR TT

TR TT

TR

Collector KAIROS CF 2.0-1

3020072

1

1

2

2

3

3

4

4

5

5

6

6

Kit hydraulic connections 1 collector CF 2.0-1

3024364 1

1

1

1

1

1

1

1

1

1

1

1

Kit hydraulic connections 1 additional collector CF 2.0-1

3024363

1

1

2

2

3

3

4

4

5

5

Roof frame kit 1 coll CF 2.0-1

3024359

1

1

1

Roof frame 2 coll CF 2.0-1

3024360

1

1

2

2

3

Roof frame 1 extension CF 2.0-1

3024361

1

1

2

2

Horizontal bars CF 2.0/2.0-1

3024249

1

2

3

4

5

6

Triangle XP 2.5V - CF 2.0/2.0-1

3024103

2

2

3

4

5

6

1

2

3

N

IN

Description

Codice

A

T

C

A

T

C

A

T

C

A

T

C

Collettore KAIROS CF 2.0-1

3020072

1

1

1

2

2

2

3

3

N N

Kit raccordi idraulici 1 coll circ. forzata CF 2.0-1

3024364 1

1

1

1

1

1

1

1

1

1

Kit raccordi idraulici 1 coll aggiuntivo CF 2.0-1 IR 3024353

1

1

1

2

2

N-1

N-1

Kit in-roof slate 1 coll CF 2.0-1

3024344 1

Kit in-roof slate 2 coll CF 2.0-1

3024345

1

1

1

Kit in-roof slate 1 additional colector CF 2.0-1

3024346

1

N-2

Kit in-roof flat tile 1 coll CF 2.0-1

3024347

1

Kit in-roof flat tile 2 coll CF 2.0-1

3024348

1

1

1

Kit in-roof flat tile 1 additional collector CF 2.0-1

3024349

1

N-2

Kit in-roof curved tile 1 coll CF 2.0-1

3024350

1

Kit in-roof curved tile 2 coll CF 2.0-1

3024351

1

A - slate

T - flat tile

C - curved tile

N - 4-5-6

| 45

COMPOSITION OF THE ROWS OF SOLAR COLLECTORS

Ecient products for the satisfaction of the user, easiness and flexibility of installation to help the installer: this perfect coupling characterizes our solar collectors and is one of the reason why Ariston’s solar products are choosen every year from millions of customer around the world. The collectors of Ariston solar range can be installed on the ground or flat roof, on sloped roof and in-roof (Kairos XP 2.5-1 V only). For any of the above mentioned installation possibility, the following tables are designed to help the installer and the end user choosing the correct installation and hydraulic accessories for any kind of solar collector.

Example of ground installation

Example of sloped roof installation

Example of in-roof installation (only Kairos XP 2.5-1V)

1

2

3

4

5

6

Description

Code

TT TR TT TR TT TR TT TR TT TR TT TR

Hydraulic connection kit 1 forced circ. coll. CF 2.0-1

Hydraulic connection kit for additional collector SYS 2.0-1

1

1

2

2

Row code

CF1TT CF1TR CF2TT CF2TR CF3TT CF3TR CF4TT CF4TR CF5TT CF5TR CF6TT CF6TR

| 46

1

2

3

N

Description

Code

A

T

C A

T

C A

T

C A

T

C

Hydraulic connection kit 1 forced circ. coll. CF 2.0-1 Hydraulic connection kit 1 additional collector CF 2.0-1 IR

1

N-2

1

1

1

Marseilles tile in-roof kit - 1 additional collector CF 2.0-1

1

N-2

1

Row code

CF1AIR CF1TIR CF1CIR CF2AIR CF2TIR CF2CIR CF3AIR CF3TIR -

-

-

-

MINIMUM EXTERNAL TEMPERATURE / PERCENTAGE

MIXTURE CONTENT

water glycol

water glycol

water glycol

water glycol

water glycol

l 150/1

18

2

15

5

15

5

-

-

-

-

20

l 200/1

22.5

2.5

20

5

17.5

7.5

-

-

-

-

25

l 200/2

22.5

2.5

20

5

17.5

7.5

-

-

-

-

25

l 300/2

22.5

2.5

20

5

17.5

7.5

-

-

-

-

25

l 200/2 CF1

12

1

10.5

2.5

9

4

8

5

6.5

6.5

13

l 200/2 CF2

8

1

7

2

6.5

2.5

5.5

3.5

4.5

4.5

9

l 300/2 CF1

16

2

14.5

3.5

12.5

5.5

11

7

9

9

18

l 300/2 CF2

16

2

14.5

3.5

12.5

5.5

11

7

9

9

18

l 400/3 CF2

20.5

2.5

18.5

4.5

16

7

14

9

11.5

11.5

23

l 500/4 CF2

25

3

22.5

5.5

19.5

8.5

17

11

14

14

28

18 - 5 m_pipe

+ 1

+ 0

+ 1

+ 0

+ 1

+ 1

+ 1

+ 1

+ 1

+ 1

+ 1

18 -10 m_pipe

+ 2

+ 0

+ 1.5 + 0.5 + 1.5

+ 1

+ 1

+ 1

+ 1

+ 1

+ 2

+ 2.5 + 1.5

+ 2

+ 2

+ 4

18 -20 m_pipe

+ 3.5 + 0.5

+ 3

+ 1

+ 3

+ 1

18 -30 m_pipe

+ 5.5 + 0.5

+ 5

+ 1

+ 4

+ 2

+ 3.5 + 2.5

+ 3

+ 3

+ 6

22 - 5 m_pipe

+ 2

+ 0

+ 1.5 + 0.5 + 1.5 + 0.5

+ 1

+ 1

+ 1

+ 1

+ 2

22 -10 m_pipe

+ 2.5 + 0.5 + 2.5 + 0.5

+ 2

+ 1

+ 2

+ 1

+ 1.5

+ 1.5

+ 3

22 -20 m_pipe

+ 5.5 + 0.5

+ 5

+ 1

+ 4

+ 2

+ 3.5 + 2.5

+ 3

+ 3

+ 6

22 -30 m_pipe

+ 8

+ 1

+ 7

+ 2

+ 6

+ 3

+ 5.5 + 3.5 + 4.5 + 4.5

+ 9

| 47

Solar Manager Pro

/ Menu simplified and quick to set-up / 7 main schemes and + 20 variants / 8 sensor inputs and 5 relay outputs / 2 PWM or 0/10V signal to drive up to 2 modulating pumps / Up to 2 extension modules via VBus®

connectable (21 sensors and 15 relays in total) / Irradiation based function to exploit solar energy / Possibility to set up by remote or by SD card / Measure and report of solar energy expoitation / Compatible with ADEME Fond Chaleur (GRS) protocol / Complete accessories range for basic and evolved functions

TECHNICAL DATA

SOLAR MANAGER PRO

Inputs

8

Outputs

4 semiconductor relays, 1 potential-free relay, 2 PWM outputs

Power supply Protection type

230

20

Ambient temperature

0 ÷ 40

Dimensions

198 x 170 x 43

170

SOLAR MANAGER PRO

CODE

3024252

| 48

Page 1 Page 2 Page 3 Page 4 Page 5 Page 6 Page 7 Page 8 Page 9 Page 10 Page 11 Page 12 Page 13 Page 14 Page 15 Page 16 Page 17 Page 18 Page 19 Page 20 Page 21 Page 22 Page 23 Page 24 Page 25 Page 26 Page 27 Page 28 Page 29 Page 30 Page 31 Page 32 Page 33 Page 34 Page 35 Page 36 Page 37 Page 38 Page 39 Page 40 Page 41 Page 42 Page 43 Page 44 Page 45 Page 46 Page 47 Page 48 Page 49 Page 50 Page 51 Page 52 Page 53 Page 54 Page 55 Page 56 Page 57 Page 58 Page 59 Page 60 Page 61 Page 62 Page 63 Page 64 Page 65 Page 66 Page 67 Page 68 Page 69 Page 70 Page 71 Page 72 Page 73 Page 74 Page 75 Page 76 Page 77 Page 78 Page 79 Page 80 Page 81 Page 82 Page 83 Page 84 Page 85 Page 86 Page 87 Page 88 Page 89 Page 90

Made with FlippingBook Annual report