EPZ 3000 - 5000
SEE DETAIL B
SEE DETAIL A
1½"x100mm (ven)
Hot domestic water tube (output)
1"x100mm (TP VALVE)
½"x100mm (T)
3"x100mm (H.W.O.)
3"x100mm (R)
½"x100mm (TR)
½"x100mm (S)
3"x100mm (R)
2"x100mm (HE)
½"x100mm (S)
3"x100mm (C.W.I.)
508
2"x40mm HE
1¼" Drain pipe
145
Flow diffuser (input)
120
D
12
Dt
1¼"x20mm anode
SCALE 0,095 DETAIL B
HE TR
Heating element Thermostat
30
Recirculation Thermometer
R T H.W.O. C.W.I. S
Hot water output Cold water input Sensor
30
100
SCALE 0,095 DETAIL A
EPZ 7000
SEE DETAIL A
SEE DETAIL B
1½"x100mm (ven)
Hot domestic water tube (output)
½"x100mm (T) 1"x100mm (TP VALVE)
4"x100mm (H.W.O.)
3"x100mm (R)
½"x100mm (TR)
SEE DETAIL C
145
2"x40mm HE
½"x100mm (S)
508
3"x100mm (R)
2"x100mm (HE)
½"x100mm (S)
1¼"x20mm anode
4"x100mm (C.W.I.)
SCALE 0,055 DETAIL B
1¼" Drain pipe
SEE DETAIL D
Flow diffuser (input)
D
120
Dt
12
C.O. C.I. HE
Coil outlet Coil inlet Heating element Thermostat
T R TR H.W.O. C.W.I. S
30
Recirculation Thermometer
Hot water output Cold water input Sensor
SCALE 0,070 DETAIL A
95
30
| 82
Made with FlippingBook Annual report