6.14 SILENCER - Silencers are manufactured from 11 and 14 gauge carbon steel. The silencers are lined with a minimum of 3” of a sound damp ing material. When installing a rectangular silencer, install on the flange side of the motor can. When installing a round silencer, install on top of the motor can (this may require a supplied cone to install) 6.15 SMOKE DETECTION – Smoke detectors are available in a variety of models. Smoke detectors should be installed by qualified individuals and in accordance with any local, state, or national codes/regulations/laws (if any). 6.16 SPRINKLERS - Unless otherwise requested, the sprinklers discharge at 165 o F. Sprinklers must be connected to the plant’s main sprinkler system and in accordance with any local, state, or national codes/regulations/laws (if any).
6.17 CUSTOM PAINT
7.0 INITIAL INSTALLATION CONSIDERATIONS
7.1 The location of the unit(s) must be planned to maximize effective operation and simultaneously afford access for service/maintenance, while keeping safety considerations at the forefront. Explosions and fires in collection systems are possible; therefore, systems should be designed and placed/affixed/mounted with those two aspects in mind and in accordance with any local, state, or national fire/safety codes/regulations. Should questions arise or assistance is needed consult your AMTECH distributor.
7.2 After the installation, access/clearance must be available to service the following components:
1. Filters 2. Fan 3. Valves 4. Controls 5. Dust storage container, such as dust drawer or dust drum.
7.3 Structural supports and hangers must be capable of supporting the load of the dust collector (plus options), the heaviest load of dust the collector can contain, and any reasonable number of maintenance technicians with a “ factor of safety ” that is acceptable to the responsible party of the equipment/building.
8.0 MECHANICAL INSTALLATION
NOTE: All mechanical installations must be performed by a qualified installer and in accordance with local, state, and national codes/regulations/laws (if any).
8.1 Prior to mounting the unit it may be advantageous to remove the cartridge filters to reduce the weight of the collector. Store filters in a safe location.
8.2 Depending on how your unit was shipped, the system may/may not have the hopper/legs/drawer attached. Should the installation require a hopper or dust drawer to be installed on the collector, the joining flanges must be sealed to eliminate air leaks. Use silicone or an equivalent high quality sealant.
NOTE: Leaks at the flanges of the hopper or dust drawer will cause excessive dust re-entrainment. Ensure no air leaks exist.