29
j5 - Pilot Igniter and Flame Rod
Flame Rod Detects presence of a flame within the burner. Connects to Fire Eye flame controller in control panel.
Pilot Gas Line Connects to pilot solenoid in control panel.
Igniter
Pilot Gas Line
Flame Rod
Igniter Energizes during the “trial for ignition” (TFI) to ignite the gas coming in from the pilot line. Connected to ignition transformer in the control panel.
j6 - Inside remote control panel
GA-1 Terminal Block Converts bare field wiring to “telephone plug” cord
PS-1 Pressure Transmitter High side connects to booth wall Low side runs outside of control panel to atmosphere. Sends DCV signal to Carel controller to indicate booth pressure. Carel controller uses the “Booth Pressure Set Point” to modulate the exhaust fan speed based on the signal this transmitter is sending.
“Telephone Plug” Communication & Power cord between remote display and Corel controller located in main control panel.
IMPORTANT – This cord should not be plugged in until proper voltage readings have been confirmed. (step c6)
29
Made with FlippingBook - professional solution for displaying marketing and sales documents online