3
a9. _____ The carel operator display is located in the remote panel. Note the functions of the buttons below.
Notifications Press to view details about system faults
Up Arrow Move selection up
Login Press to login to adjust settings
Enter Key Accept changes
Back Key Press to go back
Down Move selection down
a10. _____ This controller is where various status and values are read.
Burner Status When the burner is proven by the flame rod, this icon will appear
Current Selected Mode Winter = run the burner in spray. Summer = do not run the burner in spray . Fan Status When the fan is proven by air pressure switches, this icon will appear Booth Pressure “Digital Magnehelic” displays the pressure inside the booth vs the pressure outside of the booth. Shows if the booth is running “positive” or “negative”
Discharge Temperature Displays the temperature leaving the AMU.
Mode Displays the current mode of the system (spray, flash, cure, cool, etc.)
Countdown Displays the total time remaining for the recipe.
Recipe Displays the current selected recipe
a11. _____ To navigate through the controller, use the up down and enter keys to make selections.
Input/Output Screens: display the current digital and analog input and output signals processed by the digital controller.
Mode/Setpoints Screens: Allow personnel logged in with the User or Technician password to view and change unit operation modes and setpoints. The screens will be viewable only without entering a password. Technician Screens: Allow personnel logged in with the Technician password to view and change advanced unit modes and set points. The settings will be viewable only by users with the User password or those who are not logged in.
Information Screens: Display information about the AMU and digital controller.
3
Made with FlippingBook - professional solution for displaying marketing and sales documents online