Smart Touch 3 Oven Start-Up & Commissioning 24 Access.

Gas pressure should read between: 5 P.S.I. Maximum

2 P.S.I. Minimum

Heater Box 1 Valve Train

Heater Box 2 Valve Train

Incoming Gas Pressure_______

Incoming Gas Pressure_______

3. Press red reset button on the high and low gas pressure switches mounted to the front of the gas train. It may be necessary to remove the cover and/or press the buttons a few times.

Reset

Heater Box 1 Valve Train Reset _____ Heater Box 2 Valve Train Reset _____

4. Confirm field wiring connections are tight and that exhaust motor is wired for the correct voltage (230 or 480).

Zone 1 Exhaust Fan Connections OK_____ Zone 2 Exhaust Fan Connections OK_____

Made with FlippingBook - professional solution for displaying marketing and sales documents online