Fluke 2022 IG Test Tools Catalogue

Fluke 787B and 789 ProcessMeter™

Double the troubleshooting power so you can do more, while carrying a lot less The Fluke 787B and 789 ProcessMeter™ double troubleshooting capabilities by combining the power of a safety rated digital multimeter and mA loop calibrator into a single, compact test tool Whether you only need to source and simulate mA, or need a 24 V loop power supply, Fluke has a ProcessMeter™ test tool designed specifically to meet your needs Fluke 787B and 789 key features • 20 mA DC current source/measure/simulate • Simultaneous mA and% of scale readout • DMM designed to meet 1000 volt IEC 61010 CAT III and 600 V CAT IV standards • Fluke Connect ® compatibility for wireless data logging (with IR3000FC module) • Precision 1000 V, 440 mA true-RMS digital multimeter • Frequency measurement to 20 kHz • Min/Max/Average/Hold/Relative modes • Diode test and continuity beeper • Manual step (100%, 25%, Coarse, Fine) plus Auto Step and Auto Ramp • Externally accessible battery for easy battery changes • Three year warranty Fluke 789 additional features • 24 V loop power supply • HART mode setting with loop power (adds 250 ohm resistor)

Recommended Accessories

IR3000 FC Fluke Connect ® ir3000 Connector See page 160

TPAK ToolPak Meter Hanging Kit See page 159

80T-150UA Universal Temperature Probe See page 151

TL220 SureGrip™ Industrial

Test Lead Set See page 149

Fluke 789

Fluke 787B

80PK-8 Pipe Clamp Temperature Probe See page 151

Recommended Kits

Bundle & Save

Best Accuracy (% of reading + LSD)

Measurement Function

Range and Resolution

V DC

4000 mV, 4000 V, 4000 V, 4000 V, 1000 V 4000 mV, 4000 V, 4000 V, 4000 V, 1000 V

01% + 1

V AC (True-RMS)

07% + 2

mA DC

30000 mA

05% + 2 02% + 2

Fluke Connect ® 789 ProcessMeter™ and Temperature Kit

A DC A AC

1000 A (0440 A continuous) 1000 A (0440 A continuous)

1% + 2

Resistance

4000 O, 4000 kO, 4000 kO, 4000 kO, 40 MO, 40 MO 19999 Hz, 19999 Hz, 19999 kHz 2000 V (shows diode voltage drop) Beeps for resistance < approx 100 ohms

02% + 1

For more details see page 177

Frequency (05 Hz to 20 kHz)

005% + 1

Diode Rest Continuity

2% + 1

Included Accessories TL71 Test Lead Set, AC72 Alligator Clips, Four AA Alkaline Batteries, User Manual and Quick Reference Guide Ordering Information FLUKE-787B ProcessMeter ™ FLUKE-789 ProcessMeter ™ FLUKE-789/ T3000FC Fluke Connect 789 ProcessMeter ™ & Temperature Kit

Output Function DC Current Output (Internal Battery Operation)

Range and Resolution

Drive Capability 24 V compliance or, 1,200 ohms, @ 20 mA

Accuracy

0000 to 20000 mA or 4000 to 20000 mA, (selectable at power-up) Over-range to 24000 mA 0000 to 20000 mA or 4000 to 20000 mA, (selectable at power-up) Over-range to 24000 mA

05%

DC Current Simulate (Ext 15 V to 48 V loop supply) 24 V Loop Supply* Current Adjustment Modes

1000 ohms, @ 20 mA

05%

Minimum 24 V

250 ohms @ 20 mA > 24 V

Manual: Coarse, Fine, 25% and 100% step Automatic: Slow Ramp, Fast Ramp, 25% step

FLUKE- IR3000 FC

Fluke Connect ® Infrared Connector FlukeView ® Forms Software (incl Interface Cable)

*24 V Loop Supply available on 789 ProcessMeter TM only

FVF-SC2

C ontact your local distributor for price and availability. fluke.co/wtb

fluke co/calibration

Process Calibration Tools

105