Web Interface – Configuration

Adjust Method This Selection box will allow you to configure the Frequency adjustment configuration. 1. LTC frequency : Select Local Time Counter (LTC) frequency control 2. SyncE-DPLL : Select SyncE DPLL frequency control, if allowed by SyncE 3. Oscillator : Select an oscillator independent of SyncE for frequency control, if supported by the HW 4. LTC phase : Select Local Time Counter (LTC) phase control (assumes that the frequency is locked by means of SyncE).

Clock Frequency This will allow to set the Clock Frequency. The possible range of values are 1 - 25000000 (1 - 25MHz).

4.94.2 PTP Clock Configuration Delete

Check this box and click on 'Save' to delete the clock instance.

Inst Indicates the Instance of a particular Clock Instance [0..3]. Click on the Clock Instance number to edit the Clock details.

ClkDom Indicates the Clock domain used by the Instance of a particular Clock Instance [0..3]. More instances may use the same clock domain, e.g. a Boundary clock and a Transparent clock. Only one Slave or Boundary clock is allowed within the same Clock domain. Device Type Indicates the Type of the Clock Instance. There are five Device Types. 1. Ord-Bound - clock's Device Type is Ordinary-Boundary Clock. 2. P2p Transp - clock's Device Type is Peer to Peer Transparent Clock. 3. E2e Transp - clock's Device Type is End to End Transparent Clock.

4. Master Only - clock's Device Type is Master Only. 5. Slave Only - clock's Device Type is Slave Only. Profile Indicates the profile used by the clock.

Port List Set check mark for each port configured for this Clock Instance. One port can only be active within one Clock domain. I.e. enabling a port which is already active in another Clock domain is rejected.