Web Interface – Configuration

2 Step Flag Static member: defined by the system, true if two-step Sync events and Pdelay_Resp events are used. Clock Identity It shows unique clock identifier . One Way If true, one-way measurements are used. This parameter applies only to a slave. In one-way mode no delay measurements are performed, i.e. this is applicable only if frequency synchronization is needed. The master always responds to delay requests. Protocol Transport protocol used by the PTP protocol engine Ethernet PTP over Ethernet multicast EthernetMixed PTP using a combination of Ethernet multicast and unicast IPv4Multi PTP over IPv4 multicast IPv4Mixed PTP using a combination of IPv4 multicast and unicast IPv4Uni PTP over IPv4 unicast Note : IPv4 unicast protocol only works in Master only and Slave only clocks See parameter Device Type. In a unicast Slave only clock you also need configure which master clocks to request Announce and Sync messages from. See: Unicast Slave Configuration. VID VLAN Identifier used for tagging the PTP frames. Note: Packets are tagged if the port is configured for vlan tagging for the configured VID.

PCP Priority Code Point value used for PTP frames.

4.94.3 PTP Configuration Buttons

Add New PTP Clock: lick to create a new clock instance. Save: Click to save all changes Reset: Click to reset the page immediately.