Web Interface – Monitor
Parser State When in forwarding state, Device is forwarding non-OAMPDUs to higher sublayer. When in loopback, Device is looping back non-OAMPDUs to the lower sublayer. When in discarding state, Device is discarding non-OAMPDUs. Organizational Unique Identification 24-bit Organizationally Unique Identifier of the vendor. PDU Revision It indicates the current revision of the Information TLV. The value of this field shall start at zero and be incremented each time something in the Information TLV changes. Upon reception of an Information TLV from a peer, an OAM client may use this field to decide if it needs to be processed (an Information TLV that is identical to the previous Information TLV doesn't need to be parsed as nothing in it has changed). PDU Permission This field is available only for the Local DTE. It displays the current permission rules set for the local DTE. Possible values are:
Link fault
¾
Receive only
¾
Information exchange only
¾
ANY
¾
Discovery State Displays the current state of the discovery process. Possible states are:
Fault state
¾
Active state
¾
Passive state
¾
SEND_LOCAL_REMOTE_STATE
¾
¾ SEND_LOCAL_REMOTE_OK_STATE, SEND_ANY_STATE
5.14.2 Link OAM Port Status Buttons
Port select box:
The port select box determines which port is affected by clicking the buttons. Select a port from the drop-down list.
Auto-refresh:
Enable Auto-refresh – to refresh the page automatically every 3 seconds. Disable Auto-refresh (This is the default.)
Refresh : Click to refresh the page immediately.