Web Interface – Monitor
5.58 PTP
This page allows the user to inspect the current PTP (Precision Time Protocol) clock settings.
5.58.1 PTP External Clock Description One_PPS_Mode
Shows the current One_pps_mode configured. 1. Output : Enable the 1 pps clock output 2. Input : Enable the 1 pps clock input 3. Disable : Disable the 1 pps clock in/out-put. External Enable Shows the current External clock output configuration.
1. True : Enable the external clock output 2. False : Disable the external clock output.
Adjust Method Shows the current Frequency adjustment configuration.
1. LTC frequency : Local Time Counter (LTC) frequency control 2. SyncE-DPLL : SyncE DPLL frequency control, if allowed by SyncE 3. Oscillator : Oscillator independent of SyncE for frequency control, if supported by the HW 4. LTC phase : Local Time Counter (LTC) phase control (assumes that the frequency is locked by means of SyncE).
Clock Frequency Shows the current clock frequency used by the External Clock. The possible range of values are 1 - 25000000 (1 - 25MHz).
Confidential
User Guide: CE Services
Page 504