Web Interface – Monitor
5.58.2 PTP Clock Description Inst
Indicates the Instance of a particular Clock Instance [0..3]. Click on the Clock Instance number to monitor the Clock details. ClkDom Indicates the Clock domain used by the Instance of a particular Clock Instance [0..3]. Device Type Indicates the Type of the Clock Instance. There are five Device Types. 1. Ord-Bound - Clock's Device Type is Ordinary-Boundary Clock. 2. P2p Transp - Clock's Device Type is Peer to Peer Transparent Clock. 3. E2e Transp - Clock's Device Type is End to End Transparent Clock.
4. Master Only - Clock's Device Type is Master Only. 5. Slave Only - Clock's Device Type is Slave Only. Port List Shows the ports configured for that Clock Instance.
5.58.3 PTP Buttons Auto-refresh:
Enable Auto-refresh – to refresh the page automatically every 3 seconds Disable Auto-refresh (This is the default.)
Refresh : Click to refresh the page immediately