4.23.2.7

ICMPV6 Parameters The ICMPV6 parameters can be configured when the Frame Type is “IPv6” and the Next Header Filter is “ICMP”.

ICMP Type Filter Set or show the ICMP filter for this ACE. Any:

No ICMP filter is specified (ICMP filter status is “don’t care”) Specific: To filter a specific ICMP filter with this ACE, the user can enter a specific ICMP value. A field for entering an ICMP value appears. ICMP Type Value When “Specific” is selected for the ICMP Type Filter, the user can enter a specific ICMP value. The allowed range is 0 to 255. A frame that hits this ACE matches this ICMP value. No ICMP code filter is specified (ICMP code filter status is “don’t care”). Specific: To filter a specific ICMP code filter with this ACE, the user can enter a specific ICMP code value. A field for entering an ICMP code value appears. ICMP Code Value When “Specific” is selected for the ICMP Code Filter, you can enter a specific ICMP Code Value. The allowed range is 0 to 255. A frame that hits this ACE matches this ICMP code value. ICMP Code Filter Set or show the ICMP code filter for this ACE. Any: TCPv6/UDPv6 Parameters The TCPv6/UDPv6 parameters can be configured when the Frame Type is “IPv6” and the Next Header Filter is “TCP” or “UDP”.