Owner: SL Green Realty Corp.
BMS: Siemens Apogee 600 system.
Location: Madison Avenue and Park Avenue South, Between 24th and 25th Streets
Column Spacing: East to West typically 17’ on center. North to South typically 22’ on center.
Year Built: Phased: 1932 - 1950
Ceiling Height: (Slab to Slab height) « Lobby approximately 45’0”
Architect: D. Everett Ward and Harvey Wiley Corbett
« Floors 2-4 approximately 17’0” « Floors 5-15 approximately 13’0” « Floors 16-29 approximately 12’6”
Building Size: 2,310,056 rentable square feet
Building Height: 31 stories above ground 4 stories below ground
Security: Coordinated program of controlled electronic access (turnstiles with key- card access). Electronic surveillance and uniformed security guards on a 24/7 basis.
Floor Sizes:
Loading Dock: Six loading bays accessed from 25th street. The loading bays offer direct access to the service elevators.
4B
26,718
3B
22,831
2B
90,964
1B
73,697
1
28,337
1M
21,421
Elevators/Escalator::
« Six escalators run between the lobby and B2. « 41 passenger elevators and five freight elevators.
2
77,965
3
87,482
4
103,662
5
13,662
6
103,630
7
103,630
Electric Capacity: 6 watts per square foot.6 vaults and five KVA transformers. 5 transformers provide service to 6 switchboards adjacent to vaults in level 1B.
8
103,360
9
98,391
10
98,420
11
98,420
Generator: Caterpillar 1750 KVA generator supports base building life safety.
12
99,556
13
82,812
14
82,390
15
18,012
Floor Loads:
16
73,558
17
73,626
« Lobby and Loading Dock: 120 pounds per square foot « Rest of Property: 80 pounds per square foot
18
72,378
19
74,391
20
74,600
21
60,716
Telecom/ Cable:
22
60,710
23
48,738
« Altice Business, AT&T, Century Link, Crown Castle Fiber, Pilot Fiber, Spectrum Business, Verizon, Zayo « Wired Certified Platinum
24
48,282
25
48,282
26
49,532
27
49,472
28
48,068
29
4,376
HVAC: Central cooling plant. Operates from 8:00 AM-6:00 PM, Monday through Friday. Condenser water available for tenant supplemental cooling from separate cooling tower plant. Life Safety: Standpipe and sprinkler system with sprinkler control valves stations and fire pumps. The base building fire alarm system is a Class “E” addressable fire alarm system equipped with new command centers and central station reporting, fully integrated with the HVAC systems.
Lobby: Marble floors and walls with six separate entrances.
Façade: Curtain wall constructed of limestone and granite with fixed framed glass windows.
Construction: Concrete-encased structural steel.
BUILDING SPECIFICATIONS
Made with FlippingBook Learn more on our blog