11 Madison Tourbook

Owner: SL Green Realty Corp.

BMS: Siemens Apogee 600 system.

Location: Madison Avenue and Park Avenue South, Between 24th and 25th Streets

Column Spacing: East to West typically 17’ on center. North to South typically 22’ on center.

Year Built: Phased: 1932 - 1950

Ceiling Height: (Slab to Slab height) « Lobby approximately 45’0”

Architect: D. Everett Ward and Harvey Wiley Corbett

« Floors 2-4 approximately 17’0” « Floors 5-15 approximately 13’0” « Floors 16-29 approximately 12’6”

Building Size: 2,310,056 rentable square feet

Building Height: 31 stories above ground 4 stories below ground

Security: Coordinated program of controlled electronic access (turnstiles with key- card access). Electronic surveillance and uniformed security guards on a 24/7 basis.

Floor Sizes:

Loading Dock: Six loading bays accessed from 25th street. The loading bays offer direct access to the service elevators.

4B

26,718

3B

22,831

2B

90,964

1B

73,697

1

28,337

1M

21,421

Elevators/Escalator::

« Six escalators run between the lobby and B2. « 41 passenger elevators and five freight elevators.

2

77,965

3

87,482

4

103,662

5

13,662

6

103,630

7

103,630

Electric Capacity: 6 watts per square foot.6 vaults and five KVA transformers. 5 transformers provide service to 6 switchboards adjacent to vaults in level 1B.

8

103,360

9

98,391

10

98,420

11

98,420

Generator: Caterpillar 1750 KVA generator supports base building life safety.

12

99,556

13

82,812

14

82,390

15

18,012

Floor Loads:

16

73,558

17

73,626

« Lobby and Loading Dock: 120 pounds per square foot « Rest of Property: 80 pounds per square foot

18

72,378

19

74,391

20

74,600

21

60,716

Telecom/ Cable:

22

60,710

23

48,738

« Altice Business, AT&T, Century Link, Crown Castle Fiber, Pilot Fiber, Spectrum Business, Verizon, Zayo « Wired Certified Platinum

24

48,282

25

48,282

26

49,532

27

49,472

28

48,068

29

4,376

HVAC: Central cooling plant. Operates from 8:00 AM-6:00 PM, Monday through Friday. Condenser water available for tenant supplemental cooling from separate cooling tower plant. Life Safety: Standpipe and sprinkler system with sprinkler control valves stations and fire pumps. The base building fire alarm system is a Class “E” addressable fire alarm system equipped with new command centers and central station reporting, fully integrated with the HVAC systems.

Lobby: Marble floors and walls with six separate entrances.

Façade: Curtain wall constructed of limestone and granite with fixed framed glass windows.

Construction: Concrete-encased structural steel.

BUILDING SPECIFICATIONS

Made with FlippingBook Learn more on our blog