Cylinders
Block Cylinder Specifications
Single and Double Acting No special mounting hardware is required, just bolt down these easy to use devices. Dual position mounting, either parallel or perpendicular to piston travel, on every model. A force ranging from "minimal" to maximum cylinder capacity is adjusted by tuning the input pressure. Advance porting, for easy plumbing, is provided on both bottom and side of most models. Threaded piston ends allow the use of custom end attachments (Double Acting recommended for attachments or mechanisms). Vent port with bronze filter (Single Acting) gives the cylinder a place to "breathe" and helps keep chips and other contaminants from being drawn past wipers. Springs are designed to return the cylinder and contact points, not intended to pull mechanisms.
F-6
ILMV201100 REV F
Specifications
Piston Area (cm 2 )
Oil Capacity (cm 3 )
Cylinder Capacity (kN)** Extend Retract
Body Size (mm)
Minimum Length (mm)
Model No.
Stroke (mm)
Extend Retract
Extend Retract
Single Acting (S/A) Cylinders, actuated hydraulically 1 direction, spring returned.
42-0110-00 42-0110-01 42-0110-02 42-0110-03 42-0110-12 42-0110-04 42-0110-05 42-0110-06 42-0110-13 42-0110-14 42-0120-00 42-0120-01 42-0120-02 42-0120-03 42-0120-08 42-0120-04 42-0120-05 42-0120-06 42-0120-09 42-0120-07
6.5
60 79 71 84
1.9 5.7 6.5
10.1
N/A
28.5 x 51
2.9
N/A
N/A
19
12.5 25.5 38.1
13
17.8
N/A
44.5 x 51
5.1
N/A
N/A
100
19.3
51
112.5
26
12.5 25.5 38.1
73 86
14.5
29
39.9
N/A
51 x 63.5
11.4
N/A
N/A
98.5
43.4
51
114.5
58
Double Acting (D/A) Cylinders, actuated hydraulically both directions.
6.5
60 79 71 84
1.9 5.7 6.5
1 3
10.1
5.6
28.5 x 51
2.9
1.6
19
12.5 25.5 38.1
2.2 4.4 6.6 8.8 6.3
13
17.8
5.9
44.5 x 51
5.1
1.7
100
19.3
51
112.5
26
12.5 25.5 38.1
73 86
14.5
29
12.7
39.9
17.5
51 x 63.5
11.4
5.0
98.5
43.4
19
51
114.5
58
25.4
All dimensions are in mm.
** Cylinder capacities are listed at 350 bar (35 MPa) maximum operating pressure. The output force is adjustable by varying the hydraulic system pressure. To determine approximate output force for your application, multiply the Piston Area times Your System Operating Pressure. Actual force may vary slightly due to friction loss, seal and wiper drag and/or return spring forces.
© Vektek December 2021
Inside US 1-800-992-0236
www.vektek.com
Made with FlippingBook - Online catalogs