Vektek Metric Hydraulic Clamping Catalog

Power Supplies

.75 kW Advanced Workholding Pump Connected Convenience Packages

200-240 VAC 1 Phase

200-240 VAC 3 Phase

380-500 VAC 3 Phase

No. of Valves

2 Port Pumps - No Control Valves Included

Valve Type: Manifold Only • Central or remote power supply configured with “P” (pressure out) and “T” (tank return flow) port only • Valves usually mounted on the machine closer to the application, often machine controlled • Typically mounted behind or between 2 machines • Requires remote shear seal or poppet style zero leak valve • Supply your own off board valve

0 45-9565-00 45-9575-00 45-9595-00

Single Acting Continuous Connection - S/A Live System Valve Type: Manual 2-Position 3-Port • Can use coupled or uncoupled

• Recommended to run a continuously connected or single hose supply decoupled system • Operator interface is a manual valve handle • Pump located within operators reach Valve Type: 24VDC 2-Position 3-Port Normally Open

1 45-9565-12-1 45-9575-12-1 45-9595-12-1

• Recommended to run a continuously connected or single hose supply decoupled system where the pressurized time exceeds the unpressurized time • Operator interface is by remote pendant or can be wired into a machine controller NOTE: Should not be used with palletized systems as the valve is energized to unclamp. The unclamped time will be excessive, causing the valve to run hot.

J-7

1 2 4

45-9565-23-1 45-9565-23-2 45-9565-23-4

45-9575-23-1 45-9575-23-2 45-9575-23-4

45-9595-23-1 45-9595-23-2 45-9595-23-4

Double Acting Continuous Connection - D/A Live System Valve Type: Manual 3-Position 4-Port Closed Center • Recommended for continuously connected "live" systems

• Always connected to the fixture by means of hoses and or rotary unions • Operator interface is a manual valve handle • Pump located within operators reach Valve Type: 24 VDC 3-Position 4-Port Closed Center • Recommended for continuously connected "live" systems

1 45-9565-16-1 45-9575-16-1 45-9595-16-1

• Always connected to the fixture- by means of hoses and or rotary unions • Center position allows no movement of clamps when the valve is de-energized • Operator interface is by remote pendant or can be wired into a machine controller

1 2 4

45-9565-26-1 45-9565-26-2 45-9565-26-4

45-9575-26-1 45-9575-26-2 45-9575-26-4

45-9595-26-1 45-9595-26-2 45-9595-26-4

ILMV459503 REV C

Note: 525-600V, 3-Phase service input pumps are available upon request for all convenience packages and configurations of 45-9585-XX-X.

© Vektek December 2021

Inside US 1-800-992-0236

www.vektek.com

Made with FlippingBook - Online catalogs