Power Supplies
1.5kW Low Pressure Advanced Workholding Pump
1.5kW Advanced Workholding Pump
LOW PRESSURE
Working pressure range of 20-100 bar. Fully configurable 0-6 valve stack to meet all workholding needs. Manual or solenoid operated valves available in all configurations. Custom designed pendant for solenoid operated valves. Optional machine control cable for connection to CNC machine. Vektek electronic pressure switch with analog output to VFD for PI loop control. Return line filter with visual clog indicator is standard on all pumps. 5” Oil level site glass, drain plug, and isolation foot pads. Large filler / breather for easy oil changes and filling. In-tank fluid level sensor, electronically connected to fault circuit. 10 Micron, return line filter for maximum protection and long life. Vertical pump lift handle for use with crane or forklift. Horizontal lift handles for manual lifter and protection. Reusable buna-n rubber gaskets with PSA backing throughout. Single-stage gear pump design. Premium efficiency. VFD rated, TEFC, AC motor, 1.5kW, 3-PH, 230/460 VAC, 50/60-HZ, 1800 RPM. Variable frequency drive (VFD) motor control system, configured for electrical inputs worldwide. VFD internally protected from short circuit on all models. No duty cycle limitations due to VFD thermal protection. Large 5-gallon reservoir. 5 Screen/filter components for maximum protection of pump and devices.
Basic Pump Flow/ Pressure
8.19
6.55
4.92
3.28
1.64
.82
0
10.3
31.0
51.7
72.4
93.0
0
20.7
41.4
62.0
82.7
103.4
J-9
Pressure (bar)
ILMV457602 REVA
VERTICAL LIFT HANDLE
VFD & POWER CONTROL BOX
ELECTRONIC PRESSURE SWITCH
PENDANT I/O BLOCK
648,1
PRESSURE PORT G1/4 FEMALE
RETURN PORT G1/4 FEMALE
OIL LEVEL SIGHT GLASS
2X HORIZONTAL LIFT HANDLES
186,2
DRAIN PLUG
2X 203,2
2X 355,6 457,2 744,5
314,3
20,6
4X RUBBER FEET 1/4-20 MOUNTING HOLES
304,8
ILMV457601 REV A
RETURN LINE FILTER, VISUAL INDICATOR OPTIONAL ELECTRONIC INDICATOR
FAULT INDICATOR LIGHT RESET BUTTON
PUMP MANIFOLD USE WITH OR WITHOUT STACKING VALVES
ON/OFF/JOG CONTROL SWITCH
OIL LEVEL SWITCH OR OPTIONAL OIL LEVEL / TEMPERATURE SWITCH
LARGE FILLER / BREATHER
BASIC PUMP UNIT (SHOWN WITHOUT VALVES SEE PUMP CONFIGURATION SECTION FOR VALVE OPTIONS
Basic Workholding Pump Specifications
Pump Flow Rate Liters/Min. Avg.
Pump Pressure Range (bar)
Reservoir Capacity (Liters)
Oil Viscosity cSt @ 40 ° C
Basic Weight (kg)
Model No.
Basic
Stage 1
Stage 1
Gross Usable Min to Max No Valves
45-76X5-XX
4.1
0-100
18.9
13.2
22 to 46
79.4
© Vektek December 2021
Inside US 1-800-992-0236
www.vektek.com
Made with FlippingBook - Online catalogs