Vektek Inch Hydraulic Clamping Catalog

Miscellaneous Plumbing

Rotating Union, 4 Path

Quad Path Rotating Unions

Operating Parameter Guidelines :

- Operating Temperature Range: 40-160 F - Max. RPM see table. - Rotational torque required when no ports are pressurized: 50 in-lbs - Max. rotational torque required when ports are pressurized to 5000 PSI: 180 in-lbs - Torque requirements may vary depending on port configuration and pressure run through ports. Testing of your specific application may be required. - Air may be run in any available passage - Rotating unions are not intended to be a structural member. It is recommended that the anti-rotate arm should attach to the stationary part of the union and should be fully supported by external framework. Load on the union should be minimized. Please contact Vektek for technical assistance.

- Separate Air and fluid with extra passage between each. - Installation Instructions Available, Request IS3207

4X C Port Plugged at assembly. For manifold mounting models,

N

Body Port C

order four each adapter 30-8711-23 and discard the plugs

E

D

Body Port A

30

30

Base Port D

45

.375

P

G

D

A

B

K

I-8

Locator Hole

C

.218 .41

Circle J Bolt

F Equal sp

Body Port D

H

M

4X 1/4 Cap Screw mounting holes Equal sp on J Bolt Circle

Base Port C

B

Body Port B

2X 3/8-16 UNC .53 Equal sp on J Bolt Circle

Q

R

A

ILS321208 REV U

For proper sealing, mating surface must be flat within 0.003 in. with a maximum 32 µ in. R a surface finish.

Quad Path Dimensions Model No.

A B C D E F G H J K M N P Q R 32-4244-01 4.00 0.96 SAE 2 0.50 2.15 SAE 4 1.81 1.47 3.13 3.75 0.65 3.15 0.52 1.65 2.65 32-4264-01 4.50 1.08 SAE 2 0.56 2.41 SAE 6 1.94 1.52 3.50 4.00 0.79 3.61 0.52 1.81 3.01

Operating Limits

110 130 150 170 190

100 150 200 250 300 350 400

50 70 90

0 50

0

1000 2000 3000 4000 5000 Input Pressure (psi)

0

1000 2000 3000 4000 5000 Input Pressure (psi)

*Note: Torque requirements may vary depending on port configuration and pressure run through ports. Testing of your specific application may be required.

ILS321213 REV B