Vektek Inch Hydraulic Clamping Catalog

Push/Pull Cylinders

Cartridge Mount

Single And Double Acting  Cylinders are used when rotational swing arms are not beneficial.  Single acting are available in three retract capacities from 470 to 3,100 lbs force.  Double acting have an extend capacity of 1,200 to 6,100 lbs, with their retract capacities the same as the single acting at the same operating pressure.  Threaded plunger ends allow the attachment of arms or other mechanisms.  Also available in a straight line guided model, order as a swing clamp. Provides a long stroke in a compact body design. Can be mounted into fixture to reduce height. Hardened chrome alloy steel plungers run longer with less wear and drag than other brands. Vent port with bronze filter gives the cylinder a place to “breathe” and helps keep chips from drawing past wipers (unclamp port on double acting models).

G-8

H

Pull Cylinder

Pull Cylinder

Push/Pull Cylinder

Push/Pull Cylind

ILS251102 REV F

ILS251102 REV

Push/Pull cylinders are not shipped with cap screws.

Effective Piston Area (sq. in.)

Oil Volume (cu. in.)

Cylinder Force* (lbs.)

Model No.

Stroke (in.)

SAE Body Threads

Extend Retract

Extend Retract

Extend Retract

Single Acting (S/A)

Cylinders, actuated hydraulically 1 direction, spring returned.

25-1105-02 25-1109-10 25-1113-13

N/A N/A N/A

470

0.57 0.79 1.16 0.57 0.79 1.16

1 1/16-12 1 5/8-12 1 7/8-12 1 1/16-12 1 5/8-12 1 7/8-12

N/A N/A N/A

0.098 0.295 0.626

N/A N/A N/A

0.056 0.233 0.726

1,400 3,100

Double Acting (D/A)

Cylinders, actuated hydraulically both directions.

25-1205-02 25-1209-10 25-1213-13

1,200 3,000 6,100

470

0.249 0.601 1.227

0.098 0.295 0.626

0.142 0.475 1.423

0.056 0.233 0.726

1,400 3,100

* Cylinder Forces are calculated at 5000 psi, the maximum operating pressure. Cylinder force is adjusted by varying the hydraulic system pressure. To calculate the approximate output force for an application, multiply the Effective Piston Area by the predetermined operating pressure. The actual output force will vary slightly due to frictional losses within the assembly and/or return spring forces.

Dimensions Model No.

A

C

D

E

F

G

J

K

L

Single Acting (S/A) 25-1105-02 2.12

1.32 1.50 1.50 1.32 1.50 1.50

1.88 2.63 3.65 1.88 2.63 3.65

0.13 0.13 0.16 0.13 0.13 0.16

0.63 0.94 1.25 0.63 0.94 1.25

0.49 0.65 0.55 0.49 0.65 0.55

0.438 0.625 0.875 0.438 0.625 0.875

0.92 1.34 1.72 0.92 1.34 1.72

0.935 1.372 1.747 0.935 1.372 1.747

25-1109-10 25-1113-13

2.66 3.13

Double Acting (D/A) 25-1205-02 2.12

25-1209-10 25-1213-13

2.66 3.13

© Vektek, July 2024

800-992-0236

www.vektek.com

Made with FlippingBook - Online magazine maker